Type Designations | RSB-3601- _ _ _ – 2 _ _ – _ _ _
Ratiometric |
RSB-3601- _ _ _ – 1 1 _ – _ _ _
Analog voltage |
RSB-3601- _ _ _ – 1 2 _ – _ _ _
Analog current |
|
Electrical Data | ||||
Ouput signal | ratiometric to supply voltage 0.25 V
0.5 V (load >1 kΩ) |
0.1 … 10 V
(load >10 kΩ) |
4 … 20 mA
(burden < 500 Ω) |
|
Number of channels | 1 / 2 | 1 | 1 | |
Update rate | typical 5 | kHz | ||
Resolution | 12 | Bit | ||
Measuring range | 0 … 30 up to 0 … 360 (10°-steps) | ° | ||
Absolute linearity at measuring range 360° | < 0.8 | ±% FS | ||
Repeatability | < 0.1 | ° | ||
Hysteresis | < 0.1 | ° | ||
Temperature error at measuring range 360° | < 0.6 | < 1.6 | < 1.9 | ±% FS |
Supply voltage Ub | 5 (4.5 … 5.5) | 24 (18 … 30) | 24 (18 … 30) | VDC |
Current consumption (w/o load) | typical 15 (typ. 8 on request) per channel | mA | ||
Reverse voltage | yes, supply lines | |||
Short circuit protection | yes (vs. GND and supply voltage) | |||
Insulation resistance (500 VDC) | > 10 | MΩ | ||
Cross-section cable | 4 pole: 0.5 (AWG 20), 8 pole: 0.25 (AWG 24) | mm2 | ||
Environmental Data | ||||
MTTF (DIN EN ISO 13849-1
parts count method, w/o load, wc) |
356 (one-channel)
210 (per channel) partly redundant 388 (per channel) fully redundant |
107 | 105 | years years years |
Type designations | RMB-36_ _-2_ _-44 _- _ _ _
Supply voltage 24 VDC |
|
Electrical Data | ||
Protocol | SSI | |
Inputs | RS422-compatible, CLK-lines via optocoupler galvanically isolated | |
Monoflop time ™ | 20 ±1 | µs |
Coding | Gray, binary | |
Update rate (internal) | 1 | kHz |
Resolution | 16 or 18 across the entire measuring range | Bit |
Measuring range | see ordering specifications | |
Absolute linearity | 14 turns: < 0.036
16 turns: < 0.031 |
±% FS
±% FS |
Repeatability | < 0.5 | ° |
Hysteresis | < 1 | ° |
Temperature error | < 0.1 | ±% FS |
Supply voltage Ub | 24 (10 … 32), (5 V on request) | VDC |
Current consumption (w/o load) | typical 10 | mA |
Reverse voltage | yes, supply lines and outputs | |
Short circuit protection | yes (vs. GND, max. 1 min) | |
Ohmic load at ouputs | > 120 | Ω |
Maximum clock rate | 1 | MHz |
Insulation resistance (500 VDC) | > 10 | MΩ |
Cross-section cable | 0.25 (AWG 24) | mm2 |
Environmental Data | ||
MTTF (DIN EN ISO 13849-1
parts count method, w/o load, wc) |
173 | Years |