• CJ2M CPU13 1 1 1
  • CJ2M CPU13 1 1 1

Omron PLC CJ-series CJ2M CPU Units CJ2M-CPU15 CJ2M-CPU35

Series#: Omron PLC

Product Details

  • Omron PLC CJ-series CJ2M CPU Units CJ2M-CPU15/CPU35
  • Omron PLC Controller Module CJ2M-series
  • We are First Class Omron plc dealer and omron plc distributor in China.
  • We can Supply Omron automation parts,such as Omron PLC,Omron Servo Motor,Omron HMI,Omron VFD and Omron Relay and Omron Sensor and ect.
  • 100% Original and new,In stock by Omron Automation
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Items CJ2M-CPU11/3 CJ2M-CPU12/32 CJ2M-CPU13/33 CJ2M-CPU14/34 CJ2M-CPU15/35
User Memory 5K steps 10K steps 20K steps 30K steps 60K steps
I/O Bits 2,560 bits
Maximum Number of Connectable Units Total per CPU Rack or Expansion Rack: 10 Units max.; Total per PLC: 40 Units max.
Maximum Number of Expansion Racks 3 max.
Work Area 8,192 bits (512 words): Words W000 to W511 (Cannot be used for external I/O.)
 Holding Area 8,192 bits (512 words): Words H000 to H511Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed. Words H512 to H1535: These words can be used only for function blocks. They can be used only for function

block instances (i.e., they are allocated only for internal variables in function blocks).

  

Auxiliary Area

Read-only: 31,744 bits (1,984 words)· 7,168 bits (448 words): Words A0 to A447

· 24,576 bits (1,536 words): Words A10000 to A11535 *

Read/write: 16,384 bits (1,024 words) in words A448 to A1471 *

* A960 to A1471 and A10000 to A11535 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.

Temporary Area 16 bits: TR0 to TR15
Timer Area 4,096 timer numbers (T0000 to T4095 (separate from counters))
Counter Area 4,096 counter numbers (C0000 to C4095 (separate from timers))
 DM Area · DM Area words for Special I/O Units: D20000 to D29599 (100 words ´ 96 Units)· DM Area words for CPU Bus Units: D30000 to D31599 (100 words ´ 16 Units)

* Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.

 EM Area 32k words/bank ´ 4 banks max.: E00_00000 to E3_32767 max. ** Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
 Index Registers IR0 to IR15These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can be set so that they are unique in each task or so that they are shared by all tasks.)
Cyclic Task Flag Area 128 flags
Memory Card 128 MB, 256 MB, or 512 MB
 Operating Modes PROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in this mode.MONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to present values in I/O memory, are enabled in this mode.

RUN Mode: Programs are executed. This is the normal operating mode.

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

Boost Your Business With Industrial Automation Products From United Automation

  • Best-in-class sourcing
  • MOQ starts from 1 piece
UP