• E3X NA11 1 2
  • E3X NA11 2 2
  • E3X NA11 3 2
  • E3X NA11 2 1 1
  • E3X NA11 4 1
  • E3X NA11 1 1 1
  • E3X NA11 3 1 1
  • E3X NA11 1 2
  • E3X NA11 2 2
  • E3X NA11 3 2
  • E3X NA11 2 1 1
  • E3X NA11 4 1
  • E3X NA11 1 1 1
  • E3X NA11 3 1 1

Omron Fiber Amplifier Unit E3X-HD Sensor

Series#: Omron Fiber Sensors

Product Details

Qty:

Specification

Type Standard Model for
Sensor Communications
Unit *1
NPN output E3X-HD11 E3X-HD6 E3X-HD14 E3X-HD0
PNP output E3X-HD41 E3X-HD8 E3X-HD44
Connecting method Pre-wired Wire-saving
Connector
*2
M8
connector
Communications
Unit connector
Light source (wavelength) Red, 4-element LED (625 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (P-P) 10% max. Supplied from the connector
through the Sensor
Communications Unit
Normal mode 720 mW max.
(Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
Eco ON 530 mW max.
(Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC)
Eco LO 640 mW max. (Current consumption: 26 mA max. at
24 VDC, 53 mA max.at 12 VDC)
Control output Load power supply voltage: 26.4 VDC max., open-
collector output
Load current:
Groups of 1 to 3 Amplifier Units: 100mA max.,
Groups of 4 to 16 Amplifier Units: 20mA max.
Residual voltage:
At load current of less than 10 mA: 1 V max.,
At load current of 10 to 100 mA: 2 V max.
OFF current: 0.1 mA max.
Protection circuits Power supply reverse polarity protection, output
short-circuit protection and output reverse
polarity protection
Power supply reverse polarity
protection and output short-
circuit protection
Super-high-speed
mode (SHS) *3
NPN outputs: Operate or reset: 50 μs
PNP outputs: Operate or reset: 55 μs
High-speed Mode
(HS)
Operate or reset: 250 μs (default setting)
Standard Mode
(STND)
Operate or reset: 1 ms
Giga-power Mode
(GIGA)
Operate or reset: 16 ms
Maximum connectable Units 16 units with E3X-CRT: 16 units
with E3X-ECT: 30 units
Mutual interference
prevention
Possible for up to 10 units (optical communications sync) *3
Auto power control (APC) Always ON
Other functions Power tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot),
zero reset, resetting settings, and Eco mode
Ambient illumination
(Receiver side)
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature range OOperating:
Groups of 1 to 2 Amplifiers: -25 to 55°C,
Groups of 3 to 10 Amplifiers: -25 to 50°C,
Groups of 11 to 16 Amplifiers: -25 to 45°C
Storage: -30 to 70°C
(with no icing or condensation)
Operating:
Groups of 1 to 2 Amplifiers:
0 to 55°C,
Groups of 3 to 10 Amplifiers:
0 to 50°C,
Groups of 11 to 16 Amplifiers:
0 to 45°C,
Groups of 17 to 30 Amplifiers:
0 to 40°C
Storage: -30 to 70°C
(with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
(destruction)
10 to 55 Hz with a 1.5-mm double amplitude for
2 hours each in X, Y, and Z directions
10 to 150 Hz with a 0.7-mm
double amplitude for 80 minutes
each in X, Y, and Z directions
Shock resistance
(destruction)
500 m/s2 for 3 times each in X, Y, and Z
directions
150 m/s2 for 3 times each in
X, Y, and Z directions
Degree of protection IEC 60529 IP50
(with Protective Cover attached)
Weight
(packed state/unit only)
Approx. 105 g/
Approx. 65 g
Approx. 60 g/
Approx. 20 g
Approx. 70 g/
Approx. 25 g
Approx. 65 g/Approx. 25 g
Case Polycarbonate (PC) Heat-resistant ABS
(connector: PBT)
Cover Polycarbonate (PC)
Cable PVC
Accessories Instruction Manual

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

Boost Your Business With Industrial Automation Products From United Automation

  • Best-in-class sourcing
  • MOQ starts from 1 piece
UP