Omron Proximity Sensors E2K-C25MY1 E2K-C25MY2 E2K-C20MC1 E2K-C20MC2

Series#: Omron Proximity Sensors

Product Details

Qty:

Specification

Item Model E2K-C20MC1 E2K-C20MC2 E2K-C20MT1 E2K-C20MT2
Sensing distance

*1

20 mm
Sensing distance adjustable range 3 to 20 mm
Detectable object Conductors and dielectrics
Standard sensing object Grounded metal plate: 50 ´ 50 ´ 1 mm
Differential travel 15% max. of sensing distance (when adjusted to 20 mm ±10% with standard sensing object)
Response frequency *2 40 Hz AC power: 25 Hz, DC power: 40 Hz
Power supply voltage (operating voltage range)  

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

 

24 to 240 VAC (20 to 250 VAC), 50/60 Hz; 24 to 240 VDC (20

to 250 VDC)

Current consumption 13 mA max. at 24 VDC
 

Leakage current

 

1.5 mA max. at 24 VDC, 1.7 mA max. at 110 VAC (50/60 Hz),

2.5 mA max. at 250 VAC (50/60 Hz) Refer to Engineering Data on page 4.

Load current 250 mA max. 5 to 200 mA (resistive load)
Residual voltage 2.5 V max. (Load current: 250 mA, Cable length: 2 m) AC power: 10 V max., DC power: 8 V max. Refer to Engineering Data on page 4.
Indicators Operation indicator (yellow)
Operation mode (with sensing ob- ject approach- ing)  

C1/T1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 5 for details. C2/T2 Models: NC

Protection circuits Reverse polarity protection, Load short-circuit protection
Ambient temper- ature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of -10 to 55°C

±25% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence ±2% max. of sensing distance at the rated voltage in rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case 1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP65
Connection method *3 Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 240 g

 

Unmatched Customer Service