Type | Standard type Cable set | Long sensing range type Cable set | ||
Model NPN output | FX-101(-Z) (Note 5) |
FX-101-CC2 | FX-102(-Z) (Note 5) |
FX-102-CC2 |
Model PNP output | FX-101P(-Z) (Note 5) |
FX-101P-CC2 | FX-102P(-Z) (Note 5) |
FX-102P-CC2 |
CE marking directive compliance | EMC Directive, RoHS Directive | |||
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | |||
Power consumption | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) |
|||
Output | <NPN output type> NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (at 100 mA sink current)<PNP output type> PNP open-collector transistor • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less (at 100 mA source current) |
|||
External input | <NPN output type> NPN non-contact input • Signal condition High: +8 V to +V DC or Open Low: 0 to +2 V DC (Source current 0.5 mA or less) • Input impedance: 10 kΩ approx.<PNP output type> PNP non-contact input • Signal condition High: +4 V to +V DC (Sink current 0.5 to 3 mA) Low: 0 to +0.6 V DC or Open • Input impedance: 10 kΩ approx. |
|||
Response time | Emission frequency 0: 250 μs or less (factory default setting) Emission frequency 1: 450 μs or less Emission frequency 2: 500 μs or less Emission frequency 3: 600 μs or less |
Emission frequency 1: 2.5 ms or less (factory default setting) Emission frequency 2: 2.8 ms or less Emission frequency 3: 3.2 ms or less Emission frequency 4: 5.0 ms or less |
||
Sensitivity setting | 2-point teaching / Limit teaching / Full-auto teaching | |||
Operation indicator | Orange LED (lights up when the output is ON) | |||
Digital display | 4 digits (green) + 4 digits (red) LCD display | |||
Fine sensitivity adjustment function |
Incorporated | |||
Timer function | ON-delay / OFF-delay timer, switchable either effective or ineffective [Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms] |
|||
Emission amount setting function | 3-level + Auto setting (from production in December 2007) | |||
Interference prevention function |
Incorporated Emission frequency selection method (Note 2) (Functions at emission frequency 1, 2 or 3) |
Incorporated Emission frequency selection method (Note 2) (Functions at emission frequency 1, 2, 3 or 4) |
||
Ambient temperature |
–10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted close together: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are mounted close together: –10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ |
|||
Ambient humidity |
35 to 85 % RH, Storage: 35 to 85 % RH | |||
Ambient illuminance |
Incandescent light: 3,000 ℓx or less at the light-receiving face | |||
Voltage withstandability |
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3) | |||
Insulation resistance |
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3) | |||
Vibration resistance |
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | |||
Shock resistance |
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | |||
Emitting element (modulated) |
Red LED (Peak emission wavelength: 643 nm 0.025 mil) | |||
Material | Enclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT | |||
Connecting method | Connector (Note 4) | |||
Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | |||
Weight | Net weight: 15 g approx. Gross weight: 35 g approx. |
Net weight: 15 g approx. Gross weight: 75 g approx. |
Net weight: 15 g approx. Gross weight: 35 g approx. |
Net weight: 15 g approx. Gross weight: 75 g approx. |
Accessory | FC-FX-1 (Protection cover): 1 pc. (Note 6) |
FC-FX-1 (Protection cover): 1 pc. (Note 6) CN-14A-C2 (Connector attached cable, 2 m 6.562 ft long): 1 pc. |
FC-FX-1 (Protection cover): 1 pc. (Note 6) |
FC-FX-1 (Protection cover): 1 pc. (Note 6) CN-14A-C2 (Connector attached cable, 2 m 6.562 ft long): 1 pc. |