• JS1 12V F 2 2
  • JS1 24V F 1 2
  • JS1 24V F 2 2
  • JS1F 24V 2 2
  • JS1F 24V 3
  • JS1 12V F 2 2
  • JS1 24V F 1 2
  • JS1 24V F 2 2
  • JS1F 24V 2 2
  • JS1F 24V 3

Panasonic Power JS Relays JS1F-5V-F/-6V-F/-9V-F/-12V-F JS1F-18V-F/-24V-F/-48V-F

Series#: Panasonic Power Relays

Product Details

Qty:

Specification

Item Specifications
Contact

arrangement

Rated coil voltage Sealed Sealed Flux-resistant Flux-resistant
1 Form C 5 V DC JS1-5V-F AJS1319F JS1F-5V-F AJS1219F
1 Form C 6 V DC JS1-6V-F AJS1310F JS1F-6V-F AJS1210F
1 Form C 9 V DC JS1-9V-F AJS1315F JS1F-9V-F AJS1215F
1 Form C 12 V DC JS1-12V-F AJS1311F JS1F-12V-F AJS1211F
1 Form C 18 V DC JS1-18V-F AJS1316F JS1F-18V-F AJS1216F
1 Form C 24 V DC JS1-24V-F AJS1312F JS1F-24V-F AJS1212F
1 Form C 48 V DC JS1-48V-F AJS1313F JS1F-48V-F AJS1213F
Contact arrangement 1 Form A, 1 Form C 1 Form A Long life
Contact resistance
(Initial)
Max. 100mΩ (by voltage drop 6V DC 1A)
Contact material AgSnO2 type
Contact rating
(resistive)
10A 125V AC, 6A 277V AC,
10A 250V AC (N.O. only), 5A 30V DC
10A 125V AC, 10A 277V AC,
5A 30V DC
Max. switching power
(resistive)
2,500VA 150W (N.O.),
1,662VA 150W (N.C.)
2,770VA 150W
Max. switching voltage 277V AC, 100V DC (0.5A)
Max. switching current 10A (AC), 5A (DC)
Min. switching load
(reference value) *1
100mA, 5V DC
Insulation resistance (Initial) Min. 100MΩ (at 500V DC, Measured portion is the same as the case of dielectric strength.)
Between open contacts 750Vrms for 1 min (detection current: 10mA)
Between contact and coil 1,500Vrms for 1 min (detection current: 10mA)
Operate time Max. 10ms (at rated coil voltage, at 20°C, without bounce)
Release time Max. 10ms (at rated coil voltage, at 20°C, without bounce, without diode)
Functional Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10µs)
Destructive Min. 980 m/s2 (half-sine shock pulse: 6 ms)
Functional 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10µs)
Destructive 10 to 55 Hz (at double amplitude of 2 mm)
Mechanical life Min. 107 (switching frequency: 180 times/min)
Conditions for usage,
transport and storage *2
Ambient temperature:
–40 to +70°C (Class E),
–40 to +85°C (Class B) *3,
–40 to +105°C (Class F) *3
Humidity: 5 to 85% RH
(Avoid icing and condensation)
Ambient temperature:
–40 to +85°C (Class B) *3,
Humidity: 5 to 85% RH
(Avoid icing and condensation)
Unit weight Approx. 12 g

 