Housing | Cylindrical thread design |
Thread size | M18 x 1 |
Diameter | Ø 18 mm |
Sensing range Sn | 3 mm … 8 mm |
Safe sensing range Sa | 5.76 mm |
Installation type | Flush |
Switching frequency | 30 Hz |
Connection type | Cable, 4-wire, 2 m 1) |
Switching output | PNP |
Output function | Complementary |
Electrical wiring | DC 4-wire |
Adjustment | Potentiometer, 270° (Sensitivity) |
Enclosure rating | IP67 2) |
Supply voltage | 10 V DC … 36 V DC |
Ripple | ≤ 10 % 1) |
Voltage drop | ≤ 2.5 V DC 2) |
Current consumption | 10 mA 3) |
Time delay before availability | ≤ 100 ms |
Hysteresis | 4 % … 20 % |
Reproducibility | ≤ 5 % 4) 5) |
Temperature drift (of Sr) | ± 10 % |
EMC | According to EN 60947-5-2 6) |
Continuous current Ia | ≤ 200 mA |
Cable material | PVC |
Conductor size | 0.34 mm² |
Short-circuit protection | ✔ |
Reverse polarity protection | ✔ |
Power-up pulse protection | ✔ |
Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm |
Ambient operating temperature | –25 °C … +60 °C |
Housing material | PTFE coating, PTFE |
Housing length | 71.5 mm |
Thread length | 46.5 mm |
Tightening torque, max. | ≤ 2.6 Nm |
Items supplied | Mounting nut, PTFE plastic (2x)
Screwdriver for potentiometer adjustment (1 x) |