• ASD A3 0121 F 3 1 1
  • ASD A3 0721 L 3 1 1
  • ASD A3 0721 L 2 1
  • ASD A3 0121 L 2 1 1
  • ASD A3 0721 L 4 1
  • ASD A3 0221 L 6 1 1
  • ASD A3 0121 F 3 1 1
  • ASD A3 0721 L 3 1 1
  • ASD A3 0721 L 2 1
  • ASD A3 0121 L 2 1 1
  • ASD A3 0721 L 4 1
  • ASD A3 0221 L 6 1 1

Delta ASDA-A3 Servo Drive 400W ASD-A3-0421-L

Series#: Delta Servo Drive

Product Details

  • Delta ASDA-A3 Servo Drive 400W ASD-A3-0421-L
  • We are First Class Delta Servo Drive dealer and Delta Servo Drive distributor in China.
  • We can Supply Delta electric automation parts,such as Delta PLC,Delta Servo Motor,Delta HMI,Delta VFD and So on,
  • 100% Original and new,In stock by Delta Electric
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Delta ASDA-A3 Servo Drive 100 W 200 W 400 W 750 W 1 kW 1.5 kW 2 kW 3 kW
Delta ASDA-A3 Servo Drive 01 02 04 07 10 15 20 30
Phase / Voltage Single-phase / three-phase 220 VAC Three-phase 220 VAC
Permissible Voltage Range Single-phase / three-phase 200~230 VAC, -15%~10% Three-phase 200~230 VAC,-15%~10%
Input Current(3PH) (Units: Arms) 0.67 1.34 2.67 5.01 6.68 10.02 13.36 20.05
Input Current(1PH) (Units: Arms) 1.16 2.31 4.63 8.68 11.57 17.36
Continuous Output Current (Units: Arms) 0.9 1.55 2.65 5.1 7.3 12.6 13.4 19.4
Instantaneous Maximum Output Current (Units: Arms) 3.54 7.07 10.61 21.21 24.75 35.36 53.03 70.71
Cooling System Natural Air Circulation Fan Cooling
Drive resolution 24-bit (16777216 p/rev)
Control of Main Circuit SVPWM Control
Tuning Modes Auto / Manual
Regenerative Resistor None Built-in
Pulse Type (Only for Non-DMCNET mode) Pulse + Direction, A phase + B + CW pulse
Max. Input Pulse Frequency(Only for Non-DMCNET mode) Pulse + Direction: 4Mpps ; CCW pulse + CW pulse: 4Mpps ; A phase + B phase: Single phase 4Mpps ; Max. 200Kpps (Open collector)pps
Command Source External pulse train (PT mode) (Only for Non-DMCNET mode) / Internal parameters (PR mode)
Smoothing Strategy Low-pass and P-curve filter
Electronic Gear Electronic gear N/M multiple N: 1~536870911, M: 1~2147483647 (1/4< N/M < 262144)
Torque Limit Operation Set by parameters
Feed Forward Compensation Set by parameters
Analog Monitor Output Monitor signal can set by parameters (Output voltage range: ±8V)
Communication Interface RS-485 / CANopen / USB
Installation Site Indoor environment (free of direct sunlight), no corrosive liquid and gas (free of oil mist, flammable gas, or dust)
Altitude Altitude 2000m or lower above sea level
Atmospheric Pressure 86kPa ~ 106kPa
Operating Temperature 0ºC ~ 55ºC (If operating temperature is above 45ºC, forced cooling will be required)
Storage Temperature -20 ºC ~ 65 ºC
Humidity 0 ~ 90% RH (non-condensing)
Vibration 9.80665 m/s2 (1G) less than 20Hz, 5.88 m/s2 (0.6G) 20 to 50Hz
IP Rating IP20
Power System TN System*3*4
Approvals IEC/EN 61800-5-1,UL 508C

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

Boost Your Business With Industrial Automation Products From United Automation

  • Best-in-class sourcing
  • MOQ starts from 1 piece
UP