Delta ASDA-B3 Servo Drive EtherCAT ASD-B3-0421-E

Series#: Delta Servo Drive

Product Details

  • Delta ASDA-B3 Servo Drive EtherCAT ASD-B3-0421-E
  • We are First Class Delta Servo Drive dealer and Delta Servo Drive distributor in China.
  • We can Supply Delta electric automation parts,such as Delta PLC,Delta Servo Motor,Delta HMI,Delta VFD and So on,
  • 100% Original and new,In stock by Delta Electric
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Delta ASD-B3 servo Drive 100 W 200 W 400 W 750 W 1 kW 1.5 kW 2 kW 3 kW
Delta ASD-B3 servo Drive 01 02 04 07 10 15 20 30
Phase / Voltage Single-phase / Three-phase 220VAC Three-phase 220VAC
Permissible Voltage Single-phase / Three-phase 200 – 230VAC, -15% to 10% Three-phase200 – 230VAC, -15% to 10%
Input Current (3PH) (Unit: Arms) 0.81 1.61 4.32 8.76 9.21 9.72 14.7 16.68
Input Current (1PH) (Unit: Arms) 1.39 2.77 8.28 16.68 17.49 18.72
Continuous Output Current (Unit: Arms) 0.9 1.55 2.65 5.1 7.3 8.3 13.4 19.4
Max. Instantaneous Output Current (Unit: Arms) 3.88 7.07 10.6 16.4 21.21 27 38.3 58.9
Cooling Method Natural cooling Fan cooling
Drive Resolution 24-bit (16,777,216 pls / rev)
Main Circuit Control SVPWM control
Tuning Mode Auto / Manual
Regenerative Resistor N / A Built-in
Pulse Type (only for pulse control mode) Pulse + Direction; A phase + B phase; CCW pulse +CW pulse
Max. Output Pulse Frequency (only for pulse control mode) Pulse + direction: 4 Mpps; CCW pulse + CW pulse: 4 Mpps; A phase + B phase: single-phase 4 Mpps; Open collector: 200 Kpps
Command Source External pulse (only for pulse control mode) / Internal register (PR mode)
Smoothing Method Low-pass, S-curve, and moving filters
E-Gear Ratio E-Gear ratio: N / M times, limited to (1 / 4 < N / M < 262144) N: 1 – 536870911 / M: 1 – 2147483647
Torque Limit Parameter settings
Feed Forward Compensation Parameter settings
Analog Monitor Output Monitoring signal can be set with parameters (voltage output range: ±8V); resolution: 10-bit
Protection Function Overcurrent, Overvoltage, Undervoltage, Overheat, Regeneration error, Overload, Excessive speed deviation, Excessive position deviation, Encoder error, Adjustment error, Emergency stop, Forward / reverse limit error, Serial communication error, RST leak phase, Serial communication timeout, Short- circuit protection for terminals U, V, W
Communication Interface USB / RS-485 / CANopen / DMCNET / EtherCAT
Installation Site Indoors (avoid direct sunlight), no corrosive vapor (avoid fumes, flammable gases, and dust)
Altitude Altitude 2000 m or lower above sea level
Atmospheric Pressure 86 kPa – 106 kPa
Operating Temperature 0ºC to 55ºC (If operating temperature is above 45ºC, forced cooling is required)
Storage Temperature -20ºC to 65ºC
Humidity 0 to 90% RH (non-condensing)
Vibration 9.80665 m / s2 (1 G) less than 20 Hz, 5.88 m / s2 (0.6 G) 20 to 50 Hz
IP Rating IP20
Power System TN system *3*4
Certifications IEC/EN 61800-5-1, UL 508C

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports