• Delta CP2000 Series VFD 4 2
  • Delta CP2000 Series VFD 2 2
  • Delta CP2000 Series VFD 7 1 2
  • Delta CP2000 Series VFD 3 2
  • Delta CP2000 Series VFD 1 2
  • Delta CP2000 Series VFD 4 2
  • Delta CP2000 Series VFD 2 2
  • Delta CP2000 Series VFD 7 1 2
  • Delta CP2000 Series VFD 3 2
  • Delta CP2000 Series VFD 1 2

Delta Inverters CP2000 Series 4KW VFD040CP4EA-21 380V

Series#: Delta VFD

Product Details

  • Delta Inverters CP2000 Series 4KW VFD040CP4EA-21 380V
  • Delta VFD Inverters for Fan/Pump Vector Control Drive
  • We are First Class Delta Inverter VFDs dealer and Delta Inverter VFDs distributor in China.
  • We can Supply Delta electric automation parts,such as Delta PLC,Delta Servo Motor,Delta HMI,Delta VFD and So on,
  • 100% Original and new,In stock by Delta Electric.
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Specifications Delta Inverters CP2000 Series
Control Method Pulse Width Modulated (PWM)
 Control Mode 230 V / 460 V model:1: V / F (V / F control), 2: SVC (Sensorless Vector Control), 3: PM (Permanent Magnet Motor)

575 V / 690 V model:

1: V / F,2: SVC

Starting Torque Reach up to 150% or above at 0.5 Hz
V / F Curve 4 point adjustable V / F curve and square curve
Speed Response Ability 5 Hz
Torque Limit Light Duty: Max. 130% torque current; Normal Duty: Max. 160% torque current
Torque Accuracy ±5%
 Max. Output Frequency (Hz) 230 V model: 599.00 (55 kW and above: 400.00)460 V model: 599.00 (90 kW and above: 400.00)

575 V / 690 V model: 599.00

Frequency Output Accuracy Digital command: ±0.01%, -10 °C ~ +40 °C, Analog command: ±0.1%, 25 ±10 °C
Output Frequency Resolution Digital command: 0.01 Hz; Analog command: Max. output frequency x 0.03 / 60 Hz (±11 bit)
 Overload Tolerance Light duty: 120% of rated current for 1 minute during every 5 minutesNormal duty: 120% of rated current for 1 minute during every 5 minutes;160% of rated current for 3 seconds during every 25 seconds
Frequency Setting Signal 0 ~ +10 V, 4 ~ 20 mA, 0 ~ 20 mA
Accel. / decel. Time 0.00 ~ 600.00 / 0.0 ~ 6000.0 seconds
 

 

Main Control Function

Fault restart Torque limit High-Slip braking Dwell 3-wire sequence
 

 

Main Control Function

Speed search Parameter copy JOG frequency Slip compensation Torque compensation
 

 

Main Control Function

 S-curve accel / decel  Energy saving control Accel / Decel. Timeswitch Frequency upper / lowerlimit settings Momentary power loss ride thru
 

 

Main Control Function

PID control(with sleep function) Auto-Tuning (rotational,stationary) DC injection braking at start / stop BACnet Communication  17-step speed (max.)
 

 

Main Control Function

Over-torque detection Modbus communication (RS-485 RJ45, Max. 5.2 Kbps)
 

Fan Control

230 V model: Model with spec higher than VFD185CP23 (included) are PWM control;Model with spec lower than VFD150CP23 (not included) are on / off switch control.

460 V model: Model with spec higher than VFD220CP43/4E (included) are PWM control;

Model with spec lower than VFD185CP43/4E (not included) are on / off switch control.

575 V / 690 V model: PWM control

Motor Protection Electronic thermal relay protection
 

 

Over-Current Protection

230 V / 460 V model:Light duty: Over-current protection for 200% rated current, Normal duty: Over-current protection for 240% rated current,

Current clamp (Light duty: 130 ~ 135%);(Normal duty: 170 ~ 175%)

575 V / 690 V model:

Over-current protection for 225% rated current

Current clamp (Light duty: around 128 ~ 141%);(Normal duty: around 170 ~ 175%)

 Over-Voltage Protection 230 V model: drive will stop when DCBUS voltage exceeds 410 V 460 V model: drive will stop when DCBUS voltage exceeds 820 V 575V model: drive will stop when DCBUS voltage exceeds 1016 V 690 V model: drive will stop when DCBUS voltage exceeds 1189V
Over-Temperature Protection built-in temperature sensor
Stall Prevention Stall prevention during acceleration, deceleration and running indepenently
Restart After InstantaneousPower Failure Parameter setting up to 20 seconds
Grounding Leakage Current Protection Leakage current is higher than 50% of rated current of the AC motor drive
Short-circuit Current Rating (SCCR) Per UL508C, the drive is suitable for use on a circuit capable of delivering not more than 100kA symmetrical amperes (rms) when protected by fuses given in the fuse table

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

Boost Your Business With Industrial Automation Products From United Automation

  • Best-in-class sourcing
  • MOQ starts from 1 piece
UP