Keyence Fiber Optic Sensors FS-N41N FS-N42N FS-N43N FS-N44N

Series#: Keyence Fiber Optic Sensors

Product Details

Qty:

Specification

Model FS-N41N FS-N42N FS-N43N FS-N44N
Type Cable
Output NPN
Main unit/expansion unit Main unit Expansion unit Main unit Expansion unit
Number of control outputs 1 2
Number of external inputs 1
Light source LED Transmitter side: Red, four-element LED (wavelength: 660 nm)
Response time 23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) 23 µs (S-HSPD*7*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)
Control output Open-collector, 30 V or less 100 mA or less per output,
100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit)
Residual voltage: 1.4 V or less (output current: 10 mA or less) /2 V or less (output current: 10 to 100 mA)
External input Input time: 2 ms (ON) /20 ms (OFF) or longer*3
Unit expansion Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.
Protection circuit Protection against reverse power connection, output overcurrent, output surge, and reverse output connection
Mutual interference prevention S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)
Power supply

Power voltage

10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4
Power consumption During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V)
ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V)
ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*5
Environmental resistance

Ambient light

Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less
Ambient temperature -20 °C -4 °F to +55 °C +131 °F (no freezing)*6
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm 0.06″; 2 hours each for X, Y, and Z axes
Shock resistance 500 m/s2; 3 times each for X, Y, and Z axes
Case material Main unit and cover: polycarbonate
Weight Approx. 78 g Approx. 48 g Approx. 83 g Approx. 73 g

 