• FU 85H 1 1
  • FU 85H 3 1
  • FU 86A 2
  • FU 86A 1 2
  • FU 83C 1 1
  • FU 85H 1 1
  • FU 85H 3 1
  • FU 86A 2
  • FU 86A 1 2
  • FU 83C 1 1

Keyence Fiber Optic Sensors FU-81C FU-82C FU-83C FU-84C FU-85A FU-85H FU-85Z FU-86A

Series#: Keyence Fiber Optic Sensors

Product Details

Qty:

Specification

Model FU-81C*1
Heat resistant temperature 350°C 662°F*2
Fibre unit length 1 m39.37″ cannot be cut
Minimum bend radius R25 mm0.984″
Minimum detectable object Gold wire with a diameter of 0.005 mm0.0002″ *3
Environmental resistance Ambient temperature -30 to +350 °C -22 to 662 °F
Weight Approx. 24 g
Model FU-82C*1
Heat resistant temperature 300°C 572°F*2
Fibre unit length 1 m39.37″ cannot be cut
Minimum bend radius R25 mm0.984″
Minimum detectable object Gold wire with a diameter of 0.005 mm0.0002″ *3
Environmental resistance Ambient temperature -40 to +300 °C -40 to 572 °F
Weight Approx. 29 g
Model FU-83C*1
Heat resistant temperature 300°C 572°F*2
Fibre unit length 1 m39.37″ cannot be cut
Minimum bend radius R25 mm0.984″
Minimum detectable object Gold wire with a diameter of 0.005 mm0.0002″ *3
Environmental resistance Ambient temperature -40 to +300 °C -40 to 572 °F
Weight Approx. 23 g
Model FU-84C*1
Heat resistant temperature 300°C 572°F*2
Fibre unit length 2 m78.74″, cannot be cut
Minimum bend radius R25 mm0.984″
Minimum detectable object Object with a diameter of 0.005 mm0.0002″*3
Environmental resistance Ambient temperature -40 to +300 °C -40 to 572 °F
Weight Approx. 66 g
Model FU-85A*1
Heat resistant temperature 105°C 221°F*2*3
Fibre unit length 2 m78.74″ free-cut
Fibre unit diameter ø2.2×2
Minimum bend radius R25 mm0.984″
Minimum detectable object Gold wire with a diameter of 0.005 mm0.0002″ *4
Environmental resistance Ambient temperature -40 to +105 °C -40 to 221 °F
Weight Approx. 21 g
Model FU-85H*1
Heat resistant temperature 150°C 302°F*2*3
Fibre unit length 2 m78.74″ free-cut
Fibre unit diameter ø2.2×2
Minimum bend radius R20 mm0.787″
Minimum detectable object Gold wire with a diameter of 0.005 mm0.0002″ *4
Environmental resistance Ambient temperature -40 to +150 °C -40 to 302 °F
Weight Approx. 35 g
Model FU-85Z*1
Heat resistant temperature 100°C 212°F*2*3
Fibre unit length 2 m78.74″ free-cut
Fibre unit diameter ø2.2×2
Minimum bend radius R5 mm0.197″ Tough-Flex
Minimum detectable object Gold wire with a diameter of 0.005 mm0.0002″ *4
Weight Approx. 25 g
Model FU-86A*1
Optical axis diameter
(Standard target to be detected)
ø1 mm0.039″
Heat resistant temperature 105°C 221°F*2*3
Fibre unit length 2 m78.74″ free-cut
Fibre unit diameter ø2.2
Minimum bend radius R25 mm0.984″
Minimum detectable object Object with a diameter of 0.005 mm0.0002″*4
Weight Approx. 22 g

 