Model | IX-055 | IX-080 | IX-150 | IX-360 |
Reference distance | 55 mm 2.17″ | 80 mm 3.15″ | 150 mm 5.91″ | 360 mm 14.17″ |
Measuring distance | 45 to 65 mm 1.77″ to 2.56″ | 62 to 98 mm 2.44″ to 3.86″ | 100 to 200 mm 3.94″ to 7.87″ | 280 to 440 mm 11.02″ to 17.32″ |
Detection area
Scan mode |
Measuring distance of 45 mm 1.77″: 27.5 × 20.5 mm 1.08″ × 0.81″ (min.) Measuring distance of 55 mm 2.17″: 32.5 × 24.5 mm 1.28″ × 0.96″ (min.) Measuring distance of 65 mm 2.56″: 37.5 × 28.5 mm 1.48″ × 1.12″ (X direction) × (Y direction) *1 |
Measuring distance of 62 mm 2.44″: 36.5 × 27.0 mm 1.44″ × 1.06″ (min.) Measuring distance of 80 mm 3.15″: 45.5 × 34.0 mm 1.79″ × 1.34″ (min.) Measuring distance of 98 mm 3.86″: 54.5 × 41.0 mm 2.15″ × 1.61″ (X direction) × (Y direction) *1 |
Measuring distance of 100 mm 3.94″: 56.5 × 42.0 mm 2.22″ × 1.65″ (min.) Measuring distance of 150 mm 5.91″: 82.5 × 61.5 mm 3.25″ × 2.42″ (min.) Measuring distance of 200 mm 7.87″: 108.5 × 81.0 mm 4.27″ × 3.19″ (X direction) × (Y direction) *1 |
Measuring distance of 280 mm 11.02″: 66.0 × 49.5 mm 2.6″ × 1.95″ (min.) Measuring distance of 360 mm 14.17″: 84.0 × 63.0 mm 3.31″ × 2.48″ (min.) Measuring distance of 440 mm 17.32″: 102.0 × 76.5 mm 4.02″ × 3.01″ (X direction) × (Y direction) *1 |
Line mode | Measuring distance of 45 mm 1.77″: 27.5 mm 1.08″ × 0.81″ (min.) Measuring distance of 55 mm 2.17″: 32.5 mm 1.28″ (min.) Measuring distance of 65 mm 2.56″: 37.5 mm 1.48″ (X direction)*1 |
Measuring distance of 62 mm 2.44″: 36.5 mm 1.44″ (min.) Measuring distance of 80 mm 3.15″: 45.5 mm 1.79″ (min.) Measuring distance of 98 mm 3.86″: 54.5 mm 2.15″ (X direction)*1 |
Measuring distance of 100 mm 3.94″: 56.5 mm 2.22″ (min.) Measuring distance of 150 mm 5.91″: 82.5 mm 3.25″ (min.) Measuring distance of 200 mm 7.87″: 108.5 mm 4.27″ (X direction)*1 |
Measuring distance of 280 mm 11.02″: 66.0 mm 2.6″ (min.) Measuring distance of 360 mm 14.17″: 84.0 mm 3.31″ (min.) Measuring distance of 440 mm 17.32″: 102.0 mm 4.02″ (X direction)*1 |
Laser Light source Light source | 660 nm (visible light) wavelength red semiconductor laser | |||
Laser class | Class II laser product (FDA [CDRH] part 1040.10) , Class 2 laser product (IEC 60825-1: 2014) | |||
Output | 0.95 mW (FDA (CDRH) Part 1040.10) , 1.6 mW (IEC 60825-1: 2014) | |||
Minimum detectable object size Scan mode | ø0.7 mm ø0.03″*2 | ø1.0 mm ø0.04″*2 | ø1.7 mm ø0.07″*2 | ø1.8 mm ø0.07″*2 |
Line mode | 0.7 mm × 0.7 mm 0.03″ × 0.03″*2 | 1.0 mm × 1.0 mm 0.04″ × 0.04″*2 | 1.7 mm × 1.7 mm 0.07″ × 0.07″*2 | 1.8 mm × 1.8 mm 0.07″ × 0.07″*2 |
Repeatability | 10 µm*3 | 20 µm*3 | 50 µm*3 | 150 µm*3 |
Estimated detection | (Estimated detection: When measuring the height between two points, the minimum step difference is as follows. IX-055: 100 µm / IX-080: 200 µm / IX-150: 500 µm / IX-360: 1000 µm) *3 |
|||
Image receiving element | Monochrome CMOS image sensor | |||
Temperature characteristics | 0.04 % of F.S./°C*4 | 0.08 % of F.S./°C*4 | ||
Material | Main unit case: Zinc die-casting/Front cover: Glass, acrylic (hard coat) / Operation indicator cover: TPU/Connector ring: PBT/Connector Zinc die-casting |
|||
Weight | Approx. 190 g |
Model | IX-1000 | IX-1050 |
Main unit / expansion unit | Main unit | Expansion unit |
Display
Min. display unit |
10 µm*1 | |
Display range | ±999.99 to ±999 mm (with 4 selectable steps)*1 | |
Tools
Scan mode |
Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2 |
|
Line mode | Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2 |
|
Other functions
Common |
ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security |
|
Scan mode | Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination, Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) , Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range |
|
Line mode | Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.) | |
Input | Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) |
|
Number of inputs | 8 (IN1 to IN8) | |
Function | IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error) |
|
Analog voltage output | ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω*3 | Not available |
Analog current output | 4 to 20 mA, max. load resistance: 350 Ω*3 | |
Number of programs | 32 | |
Statistical information | Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)*1*4 |
|
Interface compatibility | CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCATⓇ / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7 | |
Number of connectible units | Main units: 1, Expansion units: 1, Communication units (DL) : 1 | |
Material | Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/ Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/ Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC |
|
Weight | Approx. 210 g | Approx. 190 g |