Model | EV-108M | EV-112M | EV-118M | EV-130M*1 |
Type | Shielded | DC , Shielded | ||
Shape | M8 | M12 | M18 | M30 |
Detecting distance | 1.5 mm 0.06″ ±10% | 2.5 mm 0.10″ ±10% | 5 mm 0.20″ ±10% | 10 mm 0.39″ ±10% |
Detectable object | Ferrous metals (see Characteristics for nonferrous metals) | |||
Standard target (iron, t=1 mm <font color=”#0099ff”>0.04″</font>) |
10 x 10 mm 0.39″ x 0.39″ | 12 x 12 mm 0.47″ x 0.47″ | 18 x 18 mm 0.71″ x 0.71″ | 30 x 30 mm 1.18″ x 1.18″ |
Hysteresis | 10% max. of detecting distance | |||
Response frequency | 800 Hz | 600 Hz | 350 Hz | 250 Hz |
Operation mode | N.O. | |||
Temperature characteristics | ±10% max. of detecting distance at 23°C 73.4°F, within -25 to +70°C -13 to +158°F |
|||
Control output (switching capacity) |
5 to 80 mA | 5 to 200 mA | ||
Protection circuit | Reversed polarity,surge voltage | Reversed polarity, short-circuit, surge voltage | ||
Cable length | 2 m 6.6′ | |||
Power voltage | 12 to 24 VDC, Ripple (P-P) 20 % or less | |||
Current consumption (leakage current) |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6′ cable) | |||
Residual voltage | Residual voltage: 3.6 V max. (with 2-m 6.6′ cable) | |||
Enclosure rating | IP67 | |||
Ambient temperature | -25 to +80 °C -13 to 176 °F (No freezing) | |||
Relative humidity | 35 to 95 % RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06″, 2 hours in each of the X, Y, and Z directions | |||
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | 1,000 m/s2, 3 times in each of the X, Y, and Z directions | ||
Case material | Stainless steel (SUS304) | Nickel-plated brass | ||
Accessories | Nut × 2, toothed washer × 1, instruction manual | |||
Weight | Approx. 42 g | Approx. 110 g | Approx. 150 g | Approx. 300 g |