Model | EV-108MSO (2091) | EV-112MSO (2062) | EV-118MSO (2063) | EV-130MSO(2064)*1 | EV-112USO (2065) | EV-118USO(2066)*1 |
Type | Shielded | Non-shielded | ||||
Shape | M8 | M12 | M18 | M30 | M12 | M18 |
Detecting distance | 1.5 mm 0.06″ ±10% | 2.5 mm 0.10″ ±10% | 5 mm 0.20″ ±10% | 10 mm 0.39″ ±10% | 8 mm 0.31″ ±10% | 15 mm 0.59″ ±10% |
Detectable object | Ferrous metals (see Characteristics for nonferrous metals) | |||||
Standard target (iron, t=1 mm <font color=”#0099ff”>0.04″</font>) |
10 x 10 mm 0.39″ x 0.39″ | 12 x 12 mm 0.47″ x 0.47″ | 18 x 18 mm 0.71″ x 0.71″ | 30 x 30 mm 1.18″ x 1.18″ | 50 x 50 mm 1.97″ | |
Hysteresis | 10% max. of detecting distance | 20% max. of detecting distance, within -10 to +70°C 14 to 158°F | ||||
Response frequency | 800 Hz | 600 Hz | 350 Hz | 250 Hz | 600 Hz | 350 Hz |
Operation mode | N.O. | |||||
Temperature characteristics | ±10% max. of detecting distance at 23°C 73.4°F, within -25 to +70°C -13 to +158°F |
±10% max. of detecting distance, within -10 to +70°C 14 to 158°F |
||||
Control output (switching capacity) |
5 to 80 mA | 5 to 200 mA | ||||
Protection circuit | Reversed polarity, surge voltage | Reversed polarity, short-circuit, surge voltage | ||||
Cable length | 500 mm19.685″ | |||||
Power voltage | 12 to 24 VDC | |||||
Current consumption (leakage current) |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6′ cable) | |||||
Residual voltage | Residual voltage: 3.6 V max. (with 2-m 6.6′ cable) | |||||
Enclosure rating | IP67 | |||||
Ambient temperature | -25 to +80 °C -13 to 176 °F (No freezing) | |||||
Relative humidity | 35 to 95 % RH (No condensation) | |||||
Case material | Stainless steel (SUS304) | Nickel-plated brass | ||||
Weight | Approx. 30 g | Approx. 55 g | Approx. 95 g | Approx. 245 g | Approx. 55 g | Approx. 140 g |