P-2501-120-285-001 (2 cups)
P-2501-120-385-001 (3 cups) |
P-2501-240-286-001 (2 cups)
P-2501-240-386-001 (3 cups) |
P-2501-345-253-001 (2 cups)
P-2501-345-353-001 (3 cups) |
||
Mechanical Data | ||||
Dimensions | see dimension drawing | |||
Mounting | clamp with 2 cylinder screws M4x10 | |||
Mechanical travel | 360 continous | ° | ||
Permitted shaft loading (axial and radial) | 15 | N | ||
static or dynamic force | ||||
Torque | < 1.5 | Ncm | ||
Maximum operational speed | 2,000 | min-1 | ||
Weight | 24 (2 cups) / 31 (3 cups) | g | ||
Electrical Data | ||||
Measuring range (dimension L) | 120 ±2 | 240 ±2 | 345 ±2 | ° |
Defined electrical range | 114 | 234 | 339 | ° |
Nominal resistance | 1 | 2 | 5 | kΩ |
Resistance tolerance | 20 | ±% | ||
Independent linearity | 0.3 | ±%FS | ||
Repeatability | 0.01 | ° | ||
Interlinearity | 1 | ±%FS | ||
Maximum permissible applied voltage | 42 | VDC | ||
Recommended wiper operating current | ≤ 1 | µA | ||
Maximum wiper current in case of mulfunction | max. 10 | mA | ||
Effective temperature coefficient | typ. 5 | ppm/K | ||
of the output-to-applied voltage ratio | ||||
Insulation resistance (500 VDC) | ≥ 10 | MΩ | ||
Dielectric strength (500 VAC, 50 Hz) | ≤ 100 | µA | ||
Environmental Data | ||||
Temperature range | -40 … +100 | °C | ||
Vibration (IEC 60068-2-6) | 5….2000
Amax = 0.75 amax = 20 |
Hz mm g | ||
Shock (IEC 60068-2-27) | 50 (11 ms) | g | ||
Life | 50×106 | movements | ||
P-2501-120-285-001 | 003266* | (angle 120°, 2-fach) | ||
P-2501-240-286-001 | 003267* | (angle 240°, 2-fach) | ||
P-2501-345-253-001 | 003268* | (angle 345°, 2-fach) | ||
P-2501-120-385-001 | 003263 | (angle 120°, 3-fach) | ||
P-2501-240-386-001 | 003264 | (angle 240°, 3-fach) | ||
P-2501-345-353-001 | 003265 | (angle 345°, 3-fach) |