Type | RSX-79_ _-_ _ _-32_-_ _ _ |
Output signal | 4 … 20 mA |
Burden | ≤ 250 Ω |
Number of channels | 1 / 2 |
Update rate | 5 kHz |
Measuring range | 60°, 120°, 180°, 240°, 300°, 360° |
Absolute linearity | Measuring range < 90°: ±2 %FS, Measuring range ≥ 90°: ±1 %FS |
Interlinearity | Measuring range < 90°: ±4 %FS, Measuring range ≥ 90°: ±2 %FS |
Resolution | 12 bits |
Repeatability | ≤ ±0.2° |
Hysteresis | typ. < ±0.1°
Only measuring range 360°: typ. < 0.25° (lower hysteresis on request) |
Temperature error | Measuring range < 90°: 200 ppm/K, Measuring range ≥ 90°: 160 ppm/K |
Supply voltage Ub | 12/24 VDC (9 … 34 VDC) |
Current consumption w/o load | typ. 20 mA per channel (Ub = 24 V) |
Polarity protection | yes (supply lines) |
Short circuit protection | yes (vs. GND and supply voltage Ub) |
Insulation resistance (500 VDC) | ≥ 10 MΩ |
Environmental Data | |
Max. operational speed | 50 rpm |
Vibration IEC 60068-2-6 | 20 g, 5 … 2000 Hz, Amax = 0.75 mm |
Shock IEC 60068-2-27 | 50 g, 6 ms |
Protection class ISO 20653 | IP67 / IP6K9K (connector M12: IP67) |
Operating temperature | -40 … +85°C |
Life | > 100 Mio. movements |
Functional safety | Suitable for safety-relevant applications according to ISO 13849 after customer validation.
Further safety data ( DCavg…) and support for functional safety are available on request. |
MTTF (IEC 60050) | 461 years (per channel) |
MTTFd (EN ISO 13849-1 parts count
method, w/o load) |
923 years (per channel) |