• Novotechnik NOVOHALL rotary sensor RFD 4000 RFC 4800 1 1
  • Novotechnik NOVOHALL rotary sensor RFD 4000 RFC 4800 1 1

Novotechnik NOVOHALL rotary sensor RFD-4000 RFC-4800

Series#: Novotechnik Rotary Sensor

Product Details

  • Novotechnik NOVOHALL rotary sensor RFD-4000 RFC-4800
  • We are First Class Novotechnik Transducer sensor dealer and Novotechnik Transducer sensor distributor in China.
  • We can Supply all kinds of  Novotechnik Transducer sensor parts,such as Novotechnik Linear Position Transducers,Novotechnik Rotary Sensor,Novotechnik Signal Conditioners and ect.
  • All parts are 100% Original and new in stock by novotechnik and fast delivery time within 1 day
  • 100% after sale service and technology Support
  • MOQ: 1pcs
Qty:

Specification

Type Designations RFC-48_ _- _ _ _ – 2 _ _ – _ _ _ RFC-48_ _- _ _ _ – 1 1 _ – _ _ _ RFC-48_ _- _ _ _ – 1 2 _ – _ _ _

ratiometric voltage current

Electrical Data
Output signal ratiometric to supply voltage 0.1 … 10 V 4 … 20 mA

0.25 … 4.75 V (5 … 95 %) (load >10 kΩ) (burden < 500 Ω)

0.5 … 4.5 V (10 … 90 %)

(load >5 kΩ)

Number of channels 1 / 2 1 1
Diagnosis activated (in case of error output signal is outside of the plausible signal range)
Update rate typical 3.4 kHz
Resolution 12 bit
Measuring range 0 … 30 up to 0 … 360, in 10°-steps °
Independent linearity < 0.5 ±% FS
Repeatability typical < 0.1 °
Hysteresis at measuring range < 360° typical < 0.1 °
Hysteresis at measuring range 360° typical < 0.25 (lower hysteresis on request) °
Temperature error at measuring range 30 up to 170° typical ±0,7 typical ±1,0 typical ±1,2 % FS
Temperature error at measuring range 180 up to 360° typical ±0,35 typical ±0,5 typical ±0,6 % FS
Supply voltage Ub 5 (4.5 … 5.5) 24 (18 … 30) 24 (13 … 30) VDC
Current consumption (w/o load) typical 12 per channel mA
Reverse voltage yes, supply lines and outputs
Short circuit protection yes (vs. GND and supply voltage)
Insulation resistance (500 VDC) > 10
Cross-section cable 0.5 (AWG 20) mm2
Environmental Data
Type Designations RFC-48_ _- _ _ _ -2 _ _ – _ _ _

ratiometric

RFC-48_ _- _ _ _ -3 _ _ – _ _ _

voltage

RFC-48_ _- _ _ _ -32 _ _ – _ _ _

current

Electrical Data
Output signal ratiometric to supply voltage Ub 0.25 … 4.75 V (5 … 95 %)

0.5 … 4.5 V (10 … 90 %)

(load >5 kΩ)

0.25 V

0.5 V

(load >10 kΩ)

4 … 20 mA

(burden @ Ub > 13 V: < 500 Ω burden @ Ub < 13 V: < 250 Ω)

Number of channels 1 / 2
Diagnosis activated (in case of error output signal is outside of the plausible signal range)
Update rate typical 3.4 kHz
Resolution 12 bit
Measuring range 0 … 30 up to 0 … 360, in 10°-steps °
Independent linearity < 0,5 ±% FS
Repeatability typical < 0,1 °
Hysteresis at measuring range < 360° Hysteresis at measuring range 360° typical < 0,1

typical < 0,25 (lower hysteresis on request)

°

°

Temperature error at measuring range 30 and 170° typical ±0.7 typical ±1.0 typical ±1.2 % FS
Temperature error at measuring range 180 and 360° typical ±0.35 typical ±0.5 typical ±0.6 % FS
Supply voltage Ub 5 (4.5 … 5.5) 12/24 (8 … 34) 12/24 (8 … 34) VDC
Current consumption (w/o load) typical 12 per channel mA
Reverse voltage yes, supply lines and outputs
Short circuit protection yes (vs. GND and supply voltage)
Insulation resistance (500 VDC) > 10
Cross-section cable / lead wires 0.5 (AWG 20) mm2
Environmental Data
Operating temperature -40 … +105

-25 … +85 with M12 connector

-40 … +105 *

-25 … +85 with M12 connector

-40 … +105 *

-25 … +85 with M12 connector

°C

°C

MTTF (DIN EN ISO 13849-1

parts count method, w/o load, wc)

99 (per channel) 44 (per channel) 40 (per channel) years
MTTFd (DIN EN ISO 13849-1 198 (per channel) 88 (per channel) 80 (per channel) years

 

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

Boost Your Business With Industrial Automation Products From United Automation