After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Type designations | TF1 – _ _ _ _ -001- 6 _ _ – 106 CANopen (available 2nd quarter 2019) | ||
Electrical Data | |||
Measured variables | Position, speed and temperature | ||
Electrical measuring range (dimension B) | 0100 up to 1000 | mm | |
Measuring range speed | 0 … 10 | ms-1 | |
Output signal / protocol | CANopen protocol to CiA DS-301 V4.2.0,
Device profile DS-406 V3.2 Encoder class 1, LSS services to CiA DS-305 V1.1.2 |
||
Programmable parameter | Cams, working areas, node-ID, baud rate | ||
Node-ID | 1 … 127 (default 127) | ||
Baud rate | 20 … 1000 | kBaud | |
Update rate (output) | 1 | kHz | |
Resolution Position Resolution Speed | 1 5
0.1 0.5 |
µm mms-1 | |
Reproducibility (rounded to resolution) Dimension B < 400 mm
Dimension B > 400 mm |
High prec mode
< 5 < 8 |
Balanced mode
< 10 < 15 |
µm µm |
Signal propagation delay | < 3 | < 1 ms | |
Hysteresis | < 5 < 10 µm | ||
Absolute linearity | < 100 ± µm | ||
Tolerance of electr. zero point | 1 | ± mm | |
Temperature error | < 15 (min. 0.01 mm/K) | ppm/K | |
Supply voltage | 24 (18 … 32) | VDC | |
Supply voltage ripple | < 10 | % Vss | |
Power drain (w/o load) | 2.4 | W | |
Overvoltage protection | 36 (permanent) | VDC | |
Polarity protection | Yes, up to supply voltage max. | ||
Short circuit protection | Yes (outputs vs. GND and supply voltage max.) | ||
Insulation resistance (500 VDC) | > 10 | MΩ | |
Bus termination internal | no (internal load resistance 120 Ω on request) | ||
Environmental Data | |||
MTTF (DIN EN ISO 13849-1
parts count method, w/o load, wc) |
> 20 | Years | |
Novotechnik TF1 Transducer | TF1-0800-001-611-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-632-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-613-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-634-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-615-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-637-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-618-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-639-106 | Digital Versions |