• 3G3MX2 A4007 V1 1
  • 3G3MX2 A4007 V1 2
  • 3G3MX2 A4007 V1 3
  • 3G3MX2 A4007 V1 1
  • 3G3MX2 A4007 V1 1
  • 3G3MX2 A4007 V1 2
  • 3G3MX2 A4007 V1 3
  • 3G3MX2 A4007 V1 1

Omron Inverter MX2 Series 3-phase 3G3MX2-A4007-V1 3G3MX2-A4015-V1

Series#: Omron VFD

Product Details

  • Omron Inverter MX2 Series 3-phase 3G3MX2-A4007-V1 3G3MX2-A4015-V1
  • Positioning functionality
  • Fieldbus communications with optional unit
  • EtherCAT, CompoNet and DeviceNet
  •  Drive Programming.
  •  Current vector Control.
  •  High Starting torque: 200% at 0.5 Hz.
  •  Safety function * EN ISO13849-1 Cat.3 PLd
  • IEC 61800-5-2 “Safe Torque Off (STO)”
  •  Speed range up to 580 Hz.
  •  When optional DeviceNet communication unit or CompoNet communication unit is mounted onto the MX2-series V1 type, the inverter will not conform to the safety standards.
Qty:

Specification

Function name Specifications
Enclosure ratings *1 Open type (IP20)
Control method Phase-to-phase sinusoidal modulation PWM
Output frequency range *2 0.10 to 400 Hz (or 580 Hz in the high-frequency mode; restrictions apply)
Frequency precision *3 Digital command: ±0.01% of the max. frequency, Analog command: ±0.2% of the max. frequency (25±10°C)
Frequency setting resolution Digital setting: 0.01 Hz, Analog setting: One-thousandth of the maximum frequency
Voltage/Frequency characteristics V/f characteristics (constant/reduced torque)Sensorless vector control, V/f control with speed feedback
Overload current rating Heavy load rating (CT): 150%/60 s Light load rating (VT): 120%/60 s
Instantaneous overcurrent protection 200% of the value of heavy load rating (CT)
Acceleration/Deceleration time 0.01 to 3600 s (linear/curve selection), acceleration/deceleration 2 setting available
Carrier frequency adjustment range 2 to 15 kHz (with derating)
Starting torque 200%/0.5 Hz (sensorless vector control)
External DC injection braking Starts at a frequency lower than that in deceleration via the STOP command, at a value set lower than that during operation, or via an external input. (Level and time settable).
 Protective functions Overcurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground fault overcur- rent at power-on status, rush current prevention circuit, overload limit, incoming overvoltage, exter- nal trip, memory error, CPU error, USP error, communication error, overvoltage suppression during deceleration, protection upon momentary power outage, emergency cutoff, etc.
Frequency settings Digital OperatorExternal analog input signal: 0 to 10 VDC/4 to 20 mA, Modbus communication (Modbus-RTU)
RUN/STOP command Digital OperatorExternal digital input signal (3-wire input supported), Modbus communication (Modbus-RTU)
Multi-function input *4 7 points (Functions can be selected from among 68)
Analog input *5 2 points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10 bits/4 to 20 mA)
Pulse input 1 point (RP terminal: 32 kHz max., 5 to 24 VDC)
Multi-function output *4 2 points (P1 and P2, Functions can be selected from among 47)
Relay output *4 1 point (SPDT contact (MC, MA, MB), Functions can be selected from among 47)
Analog output (Frequency monitor)*6 1 point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current selectable)
Pulse output 1 point (MP terminal: 32 kHz max., 0 to 10 V)
RS-422 RJ45 connector (for Digital Operator)
RS-485 Control circuit terminal block, Modbus communication (Modbus-RTU)
USB USB1.1, mini-B connector
  

Other functions

AVR function, V/f characteristics switching, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S shape acceleration/deceleration, electronic thermal characteristics, level adjustment, restart function, torque boost function, fault monitor, soft lock function, frequency conversion display, USP function, motor 2 control function, UP/DWN, overcurrent control function, etc.
Ambient operating temperature *7 -10 to 50°C (However, derating is required).
Ambient storage temperature -20°C to 65°C
Ambient operating humidity 20% to 90% RH (with no condensation)
Vibration resistance 5.9 m/s2 (0.6G), 10 to 55 Hz
Application environment At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
EtherCAT Communication Unit 3G3AX-MX2-ECT
CompoNet Communication Unit 3G3AX-MX2-CRT-E
DeviceNet Communication Unit 3G3AX-MX2-DRT-E