Contact resistance | 100 mW max. |
Operate time | 10 ms max. |
Release time | 5 ms max. |
Bounce time | Operate: Approx. 0.6 ms Release: Approx. 7.2 ms |
Max. switching frequency | Mechanical: 18,000 operations/hrElectrical: 1,800 operations/hr (under rated load) |
Insulation resistance | 100 MW min. (at 500 VDC) |
Dielectric strength | 750 VAC, 50/60 Hz for 1 min between contacts of same polarity 2,000 VAC, 50/60 Hz for 1 min between coil and contacts |
Impulse withstand voltage | 4,500 V between coil and contacts |
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude Malfunction: 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance | Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 100 m/s2 (approx. 10G) |
Life expectancy | Mechanical:10,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr) |
Ambient temperature | Operating: –40°C to 85°C |
Ambient humidity | Operating: 35% to 85% |
Weight | Approx. 12 g |