Sensing method | Through-beam | Retro-reflective | Diffuse-reflective | |||
NPN out- put Pre-wired Models | E3Z-T61K | E3Z-R61K | E3Z-D61K | E3Z-D62K | ||
M8 Pre-wired connector | E3Z-T61K-M3J | E3Z-R61K-M3J | E3Z-D61K-M3J | E3Z-D62K-M3J | ||
PNP out- put Pre-wired Models | E3Z-T81K | E3Z-R81K | E3Z-D81K | E3Z-D82K | ||
M8 Pre-wired connector | E3Z-T81K-M3J | E3Z-R81K-M3J | E3Z-D81K-M3J | E3Z-D82K-M3J | ||
Sensing distance |
15 m |
3 m (150 mm) *
(when using E39-R1S) 2 m (100 mm) * (when using E39-R1) |
100 mm
(white paper: 100 ´ 100 mm) |
1 m
(white paper: 300 ´ 300 mm) |
||
Standard sensing object | Opaque: 12-mm dia. min. | Opaque: 75-mm dia. min. | — | |||
Differential travel | — | 20% max. of setting distance | ||||
Directional angle | Both emitter and receiver: 3 to 15° | 2 to 10° | — | |||
Light source (wavelength) | Infrared LED (870 nm) | Red LED (660 nm) | Infrared LED (860 nm) | |||
Current consumption |
35 mA max. (Emitter: 15 mA max., Receiver: 20 mA max.) |
30 mA max. |
||||
Protection circuits |
Reversed power supply polarity protection, Output short-circuit protection, and Reversed output po- larity protection |
Reversed power supply polarity protection, Output short-circuit protection, Mutual in- terference prevention, and Reversed output polarity protection |
||||
Response time | Operate or reset: 1 ms max. | |||||
Degree of protection | IP67 (IEC), Oil resistant models: IP67 (IEC) (in-house standards: oilproof), excluding cables and connectors | |||||
Connection method | Pre-wired cable (standard length: 2 m), M8 Pre-wired Connector | |||||
Pre-wired cable (2 m) | Approx. 120 g | Approx. 65 g | ||||
Connector (M8, 4 pins) | Approx. 50 g | Approx. 30 g | ||||
Case | PBT (polybutylene terephthalate) | |||||
Lens | Modified polyarylate | Methacrylic resin | Modified polyarylate | |||
Power supply voltage | 12 to 24 VDC±10%, ripple (p-p): 10% max. | |||||
Control output |
Load power supply voltage: 26.4 VDC max., Load current: 100 mA max. Residual voltage: Load current of less than 10 mA: 1 V max.
Load current of 10 to 100 mA: 2 V max. Open collector output (NPN/PNP depending on model) Light-ON/Dark-ON selectable |
|||||
Sensitivity adjustment | One-turn adjuster | |||||
Ambient illumination (Receiver side) | Incandescent lamp: 3,000 lx max. Sunlight: 10,000 lx max. | |||||
Ambient temperature range | Operating: -25 to 55°C, Some connector models: -40°C to 55°C * (with no icing or condensation) Storage: -40 to 70°C (with no icing or condensation) | |||||
Ambient humidity range | Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | |||||
Insulation resistance | 20 MΩ min. at 500 VDC | |||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min | |||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||||
Indicator |
Operation indicator (orange) Stability indicator (green)
Through-beam Emitter has power indicator (orange) only. |
|||||
Accessories | Instruction manual (Neither Reflectors nor Mounting Brackets are provided with any of the above models.) |