Omron PLC CS Series Analog I/O Units CS1W-MAD44

Series#: Omron PLC

Product Details

  • Omron PLC CS Series Analog I/O Units CS1W-MAD44
  • Omron PLC Controller Module CP-series
  • We are First Class Omron plc dealer and omron plc distributor in China.
  • We can Supply Omron automation parts,such as Omron PLC,Omron Servo Motor,Omron HMI,Omron VFD and Omron Relay and Omron Sensor and ect.
  • 100% Original and new,In stock by Omron Automation
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Item CS1W-MAD44
Applicable PLC model CS series
Unit type CS1 Special I/O Unit
Isolation Between I/O and PLC signals: Photocoupler (No isolation between individual I/O signals.)
External terminals 21-point detachable terminal block (M3 screws)
Power consumption 200 mA max. at 5 VDC, 200 mA max. at 26 VDC
Dimensions (mm) *1 35 ´ 130 ´ 126 (W ´ H ´ D)
Weight 450 g max.
General specifications Conforms to general specifications for SYSMAC CS-series Series.
Mounting position CS-series CPU Rack or CS-series Expansion Rack

(Cannot be mounted to a C200H Expansion I/O Rack or a SYSMAC BUS Slave Rack.)

 

 

 

Maximum number of Units

 

 

Units per Rack (CPU Rack or Expansion Rack) *2

Power Supply Unit Maximum number of Units per Rack
C200HW-PA204 C200HW-PA204S C200HW-PA204R C200HW-PD024  

3 Units max.

C200HW-PA209R 6 Units max.
Units per basic system When C200HW-PA209R Power Supply Units only are used: 6 Units max. ´ 8 Racks = 48 Units max.
 

 

 

 

 

Data exchange with CPU Units

 

Special I/O Unit Area

CIO 200000 to CIO 295915

(Words CIO 2000 to CIO 2959)

 

 

Exchanges 10 words of data per Unit.

CPU Unit to Analog I/O Unit Analog output Peak value hold

Conversion Enable Bit

Analog I/O Unit to CPU Unit Analog input

Input disconnection detection Alarm flags

 

 

Internal Special I/O Unit DM Area (D20000 to D29599)

 

 

Transmits 100 words of data per Unit at power-up or when the Unit is restarted.

 

 

CPU Unit to Analog I/O Unit

Input signal conversion enable/disable, input signal range setting

Output signal conversion enable/disable, output signal range setting

Ratio conversion function setting, constants

Output status for output hold Mean value function setting

 

 

 

 

 

 

 

 

 

 

Input Specifications

Input signal *4 Voltage input Current input
Number of analog inputs 4
 

Input signal range *3

1 to 5 V

0 to 5 V

0 to 10 V

-10 to 10 V

 

4 to 20 mA

Maximum rated input (for 1 point) *5 ±15 V ±30 mA
Input impedance 1 MΩ min. 250 Ω (rated value)
Resolution 4,000 (full scale)
Converted output data 16-bit binary data
Accuracy *6 23±2°C ±0.2% of full scale ±0.4% of full scale
0°C to 55°C ±0.4% of full scale ±0.6% of full scale
A/D conversion time *7 1.0 ms/point max.
 

 

Functions

 

Mean value processing

Stores the last “n” data conversions in the buffer, and stores the the mean value of the conversion values.

Buffer number: n = 2, 4, 8, 16, 32, 64

Peak value holding Stores the maximum conversion value while the Peak Value Hold Bit is ON.
Input disconnection detection *9 Detects the disconnection and turns ON the Disconnection Detection Flag.