• CS1D PD025 1
  • CS1D PD025 1
  • CS1D PD025 1
  • CS1D PD025 1

Omron PLC CS1D Power Supply Unit CS1D-PA207R CS1D-PD024 CS1D-PD025

Series#: Omron PLC

Product Details

  • Omron PLC CS1 Series CPU Backplane CS1W-BC022 CS1W-BC032 CS1W-BC052
  • High performance controller
  • SYSMAC CS1 PLC has high responsiveness, and data I/O control function,
  • thus greatly shorten the processing time and move to higher control precision machinery and equipment.
  • Artificial efficiency:User friendly development environment
  • inheritance:Efficient use of important assets
  • support in the case of without any change to use existing units and the procedure.
  • Using the improved CS1 series PLC advanced system can be extended to the ideal size
  • A total of nine CPU unit model can provide wide application, from small system to large systems.
  • Product series include memory card, serial communication, plate and function of all kinds of high I/O unit can be used with any CPU units
  • flexible created to meet the requirements of the system.
Qty:

Specification

Item Power Supply Unit Specifications
CS1D-PA207R CS1D-PD024 CS1D-PD025
Power supply voltage 100 to 120 V AC/200 to 240 V, 50/60 Hz 24 V DC
Operating voltage range 85 to 132 V AC/170 to 264 V 19.2 to 28.8 V DC
Power consumption 150 VA max. 40 W max. 60 W max.
Inrush current 100 to 120 V AC: 30 A max.

200 to 240 VAC: 40 A max.

30 A max.
Power supply output capacity 5 V DC, 7 A (including the CPU Unit power supply) 26 V DC, 1.3 A

Total: 35 W

5 V DC, 4.3 A (including the CPU Unit power supply)

26 V DC, 0.56 A

Total: 28 W

5 V DC, 5.3 A (including the CPU Unit power supply)

26 V DC, 1.3 A

Total: 40 W

Power supply output terminal Not provided.
RUN output *1 Contact configuration: SPST-NO Switch capacity:

240 V AC, 2 A (resistive load) 120 V AC, 0.5 A (induction load) 24 V DC, 2 A (resistive load)

24 VDC, 2 A (induction load)

Not provided.
Insulation resistance 20 MΩ min. (at 500 V DC) between AC external and GR terminals *2 20 MΩ min. (at 500 V DC) between DC external and GR terminals *2
Dielectric strength Between AC external and GR terminals *2: 2,300 V AC 50/60 Hz for 1 min

Leakage current: 10 mA max.

Between DC external and GR terminals *2: 1,000 V AC 50/60 Hz for 1 min

Leakage current: 10 mA max.

Between DC external and GR terminals *2: 1,000 V AC 50/60 Hz for 1 min

Leakage current: 10 mA max.

Noise immunity 2 kV on power supply line (conforming to IEC61000-4-4)
Vibration resistance 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes (Time coefficient: 8 minutes ´ coefficient factor 10 = total time 80 minutes)

(When mounted on a DIN Track: 2 to 55 Hz, acceleration of 2.9 m/s2 in X, Y, and Z directions for 20 minutes) (conforming to IEC60068-2-6)

Shock resistance 147 m/s2 3 times each in X, Y, and Z directions (conforming to IEC60068-2-27)
Ambient operating temperature 0 to 55°C
Ambient operating humidity 10% to 90% (with no condensation)
Atmosphere No corrosive gases
Ambient storage temperature -20 to 75°C (excluding battery)
Grounding Less than 100 Ω
Enclosure Mounted in a panel.
Weight Each Rack: 6 kg max.
CPU Rack dimensions (mm) CS1D-BC052 (5 slots, Duplex CPU System) and CS1D-BI082S (8 slots, Single CPU System): 505 ´ 132 ´ 123 mm (W ´ H ´ D) *2