• CS1D PD025 1 1
  • CS1D PD025 1 1

Omron PLC Transmitter Input Unit CS1W-PTW01

Series#: Omron PLC

Product Details

  • Omron PLC Transmitter Input Unit CS1W-PTW01
  • Omron PLC Controller Module CP-series
  • We are First Class Omron plc dealer and omron plc distributor in China.
  • We can Supply Omron automation parts,such as Omron PLC,Omron Servo Motor,Omron HMI,Omron VFD and Omron Relay and Omron Sensor and ect.
  • 100% Original and new,In stock by Omron Automation
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Item Specifications
Model CS1W-PTW01
Applicable PLC CS Series
Unit type CS-series Special I/O Unit
Mounting position CS-series CPU Rack or CS-series Expansion Rack (Cannot be mounted to C200H Expansion I/O Rack or SYSMAC BUS Remote I/O Slave Rack.)
Maximum number of Units 80 (within the allowable current consumption and power consumption range)
Unit numbers 00 to 95 (Cannot duplicate Special I/O Unit numbers.)
Number of inputs 4
Sensor type Unified signal from transmitter (4 to 20 mA), 4 to 20 mA, 1

to 5 V

Sensor type and scaling to industrial units are separate for each of the 4 inputs.

Note: Sensor type and scaling to industrial units are set in the DM Area.

Example:

Input signal type: 4 to 20 mA from 2-wire transmitter; industrial unit scaling: 0 to 500 m3/h (after square root extraction). DM Area settings are as follows:

Input signal type: 0 (0000 hex)

Industrial unit maximum value stored: 500 (01F4 hex) Industrial unit minimum value stored: 0 (0000 hex)

 

User-defined scaling in industrial units

Scaling required for 4 to 20 mA or 1 to 5 V. (Any minimum and maximum values can be set.) (4 inputs set separately.)
 

 

Data storage in the CIO Area

The value derived from carrying out the following processing in order of the process value data is stored in four digits hexadecimal (binary values) in the allocated words in the CIO Area.

1) Mean value processing ® 2) Scaling ® 3) Zero/span adjustment ® 4) Square root extraction ® 5) Output limits

Accuracy (25°C) ±0.2% of full scale
Temperature coefficient ±0.015%/°C of full scale
Resolution 1/4,096 of full scale
Input signal range -15 to 115%
 

 

Power supply for 2-wire transmitter

Output voltage: 24 V DC ±15% for each input (without load) Current capacity: 22 mA max. for each input

Short-circuit control current: 22 to 27 mA Allowable short-circuit time:

Ambient temperature less than 40°C: No limit Ambient temperature 40 to 55°C: 10 min or less

Input impedance 4 to 20 mA for 2-wire transmitter: 250 Ω; 4 to 20 mA: 250 Ω; 1 to 5 V: 1 MΩ min.
Warmup time 10 min
Response time 0.5 s (travel time from input 0% to 90%, for step input)
Conversion period 100 ms/4 inputs
Maximum time to store data in CPU Unit Conversion period + one CPU Unit cycle
Input error detection Error detected when under -17.2% (4 to 20 mA: 1.25 mA; 1 to 5 V: 0.3125 V) or over 112.5% (4 to 20 mA: 22 mA; 1

to 5 V: 5.5 V).