Item | G9EA-1(-B) | G9EA-1(-B)-CA |
Contact resistance (See note 2.) | 30 mW max. (0.6 mW typical) | 10 mW max. (0.3 mW typical) |
Contact voltage drop | 0.1 V max.
(for a carry current of 60 A) |
0.1 V max.
(for a carry current of 100 A) |
Operate time | 50 ms max. | |
Release time | 30 ms max. | |
Between coil and contacts | 1,000 MW min. | |
Between contacts of the same polarity | 1,000 MW min. | |
Between coil and contacts | 2,500 VAC, 1 min | |
Between contacts of the same polarity | 2,500 VAC, 1 min | |
Impulse withstand voltage (See note 4.) | 4,500 V | |
Destruction | 10 to 55 to 10 Hz, 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2) | |
Malfunction | 10 to 55 to 10 Hz, 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2) | |
Destruction | 490 m/s2 | |
Malfunction | 196 m/s2 | |
Mechanical endurance (See note 5.) | 200,000 ops. min. | |
Electrical endurance (See note 6.) | 120 VDC, 100 A, 3,000 ops. min. | 400 VDC, 30 A, 1,000 ops. min. |
400 VDC, 60 A, 3,000 ops. min. | 120 VDC, 30 A, 2,500 ops. min. | |
400 VDC, 30 A, 30,000 ops. min. | — | |
Short-time carry current | 100 A (10 min) | 150 A (10 min) |
Maximum interruption current | 600 A at 300 VDC (5 times) | — |
Overload interruption | 180 A at 400 VDC (100 times min.) | 100 A at 120 VDC (150 times min.) |
Reverse polarity interruption | –60 A at 200 VDC (1,000 times min.) | — |
Ambient operating temperature | –40 to 70°C (with no icing or condensation) | |
Ambient operating humidity | 5% to 85% | |
Weight | Approx. 310 g |