Omron Proximity Sensors E2K-C25ME1/-C25ME2 2M E2K-C25MF12M/-C25MF22M

Series#: Omron Proximity Sensors

Product Details

Qty:

Specification

Item Model E2K-C25M@1 E2K-C25M@2 E2K-C25MY1 E2K-C25MY2
Sensing distance

*

25 mm
Sensing distance adjustable range 3 to 25 mm
Detectable object Conductors and dielectrics
Standard sensing object Grounded metal plate: 50 ´ 50 ´ 1 mm
Differential travel 15% max. of sensing sensing distance (when adjusted to 25 mm ±10% with standard sensing object)
Response frequency 70 Hz 10 Hz
Power supply voltage (operating voltage range)  

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

 

100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Current consumption E and F Models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC
Leakage current Y Models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF, 2 mA max. at 200 VAC (50/60 Hz) with output turned OFF
 

Load current

200 mA max. 5 to 200 mA (resistive load)
Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m) Refer to Engineering Data on page 4.
Indicators Detection indicator (red) Operation indicator (red)
Operation mode (with sensing object approach- ing)  

E1, F1, and Y1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 5 for details. E2, F2, and Y2 Models: NC

Protection circuits Reverse polarity protection, Surge suppressor Surge suppressor
Ambient temper- ature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of -10 to 55°C

±25% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

 

Voltage influence

±2% max. of sensing distance at the rated voltage in rated voltage ±15% range ±2% max. of sensing distance at the rated voltage in rated voltage +20%, -10% range at 100 VAC, ±20% range at 200 VAC
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case 1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP66
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 200 g

 