Item Model | E2K-C25M@1 | E2K-C25M@2 | E2K-C25MY1 | E2K-C25MY2 |
Sensing distance
* |
25 mm | |||
Sensing distance adjustable range | 3 to 25 mm | |||
Detectable object | Conductors and dielectrics | |||
Standard sensing object | Grounded metal plate: 50 ´ 50 ´ 1 mm | |||
Differential travel | 15% max. of sensing sensing distance (when adjusted to 25 mm ±10% with standard sensing object) | |||
Response frequency | 70 Hz | 10 Hz | ||
Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
100 to 220 VAC (90 to 250 VAC), 50/60 Hz |
||
Current consumption | E and F Models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC | |||
Leakage current | Y Models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF, 2 mA max. at 200 VAC (50/60 Hz) with output turned OFF | |||
Load current |
200 mA max. | 5 to 200 mA (resistive load) | ||
Residual voltage | 2 V max. (Load current: 200 mA, Cable length: 2 m) | Refer to Engineering Data on page 4. | ||
Indicators | Detection indicator (red) | Operation indicator (red) | ||
Operation mode (with sensing object approach- ing) |
E1, F1, and Y1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 5 for details. E2, F2, and Y2 Models: NC |
|||
Protection circuits | Reverse polarity protection, Surge suppressor | Surge suppressor | ||
Ambient temper- ature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -10 to 55°C
±25% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|||
Voltage influence |
±2% max. of sensing distance at the rated voltage in rated voltage ±15% range | ±2% max. of sensing distance at the rated voltage in rated voltage +20%, -10% range at 100 VAC, ±20% range at 200 VAC | ||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | 1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | ||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP66 | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||