• TL N10ME1 2
  • TL N10ME1 7 2
  • TL N10ME1 8 1
  • TL N10ME1 6 2
  • TL N10ME1 2
  • TL N10ME1 7 2
  • TL N10ME1 8 1
  • TL N10ME1 6 2

Omron Proximity Sensors TL-N5MY1 TL-N5MY2 TL-N10ME1 TL-N10ME2

Series#: Omron Proximity Sensors

Product Details

Qty:

Specification

Item Model TL-Q2MC1 TL-Q5MC@/TL-Q5MB1
Sensing distance 2 mm ±15% 5 mm ±10%
Set distance 0 to 1.5 mm 0 to 4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 6.)
Standard sensing object Iron, 8 ´ 8 ´ 1 mm Iron, 15 ´ 15 ´ 1 mm
Response time 2 ms max.
Response frequency * 500 Hz
Power supply volt- age (operating volt- age range)  

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Current consumption 15 mA max. at 24 VDC (no-load) 10 mA max. at 24 VDC
Load current  

NPN open collector

100 mA max. at 30 VDC max.

TL-Q5MC@: NPN open collector,

50 mA max. at 30 VDC max.

TL-Q5MB@: PNP open collector,

50 mA max. at 30 VDC max.

Residual voltage 1 V max. (under load current of 100 mA with cable length of 2 m) 1 V max. (under load current of 50 mA with cable length of 2 m)
Indicators Detection indicator (red)
Operation mode (with sensing object approaching) NO B1/C1 Models: NO C2 Models: NC
Protection circuits Reverse polarity protection, Surge suppressor
Ambient temperature range Operating/Storage: -10 to 60°C (with no icing or condensa- tion) Operating/Storage: -25 to 70°C (with no icing or condensa- tion)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -10 to 60°C ±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case 5 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC for 1 min between current-carrying parts and case 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z direc- tions Destruction: 200 m/s2 10 times each in X, Y, and Z direc- tions
Degree of protection IEC 60529 IP67,

in-house standards: oil-resistant

IEC IP67
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 60 g Approx. 90 g