• 3G3MX2 A2002 V1 5
  • 3G3MX2 A2002 V1 6
  • 3G3MX2 A2002 V1 4
  • 3G3MX2 A2002 V1 3
  • 3G3MX2 A2002 V1 2
  • image
  • 3G3MX2 A2002 V1 5
  • 3G3MX2 A2002 V1 6
  • 3G3MX2 A2002 V1 4
  • 3G3MX2 A2002 V1 3
  • 3G3MX2 A2002 V1 2
  • image

Omron VFD Frequency Inverter 3 phase MX2 Series 3G3MX2-A4055-ZV1

Series#: Omron VFD

Product Details

  • Omron VFD Frequency Inverter 3 phase MX2 Series 3G3MX2-A4055-ZV1
  • We are First Class Omron VFD Frequency Inverter dealer and Omron VFD Frequency Inverter distributor in China.
  • We can Supply Omron automation parts,such as Omron PLC,Omron Servo Motor,Omron HMI,Omron VFD and Omron Relay and Omron Sensor and ect.
  • 100% Original and new,In stock by Omron Automation
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Function name Specifications
Enclosure ratings *1 Open type (IP20)
Control method Phase-to-phase sinusoidal modulation PWM
Output frequency range *2 0.10 to 400 Hz (or 580 Hz in the high-frequency mode; restrictions apply)
Frequency precision *3 Digital command: ±0.01% of the max. frequency, Analog command: ±0.2% of the max. frequency (25±10°C)
Frequency setting resolution Digital setting: 0.01 Hz, Analog setting: One-thousandth of the maximum frequency
Voltage/Frequency characteristics V/f characteristics (constant/reduced torque)Sensorless vector control, V/f control with speed feedback
Overload current rating Heavy load rating (CT): 150%/60 s Light load rating (VT): 120%/60 s
Instantaneous overcurrent protection 200% of the value of heavy load rating (CT)
Acceleration/Deceleration time 0.01 to 3600 s (linear/curve selection), acceleration/deceleration 2 setting available
Carrier frequency adjustment range 2 to 15 kHz (with derating)
Starting torque 200%/0.5 Hz (sensorless vector control)
External DC injection braking Starts at a frequency lower than that in deceleration via the STOP command, at a value set lower than that during operation, or via an external input. (Level and time settable).
 Protective functions Overcurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground fault overcur- rent at power-on status, rush current prevention circuit, overload limit, incoming overvoltage, exter- nal trip, memory error, CPU error, USP error, communication error, overvoltage suppression during deceleration, protection upon momentary power outage, emergency cutoff, etc.
Frequency settings Digital OperatorExternal analog input signal: 0 to 10 VDC/4 to 20 mA, Modbus communication (Modbus-RTU)
RUN/STOP command Digital OperatorExternal digital input signal (3-wire input supported), Modbus communication (Modbus-RTU)
Multi-function input *4 7 points (Functions can be selected from among 68)
Analog input *5 2 points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10 bits/4 to 20 mA)
Pulse input 1 point (RP terminal: 32 kHz max., 5 to 24 VDC)
Multi-function output *4 2 points (P1 and P2, Functions can be selected from among 47)
Relay output *4 1 point (SPDT contact (MC, MA, MB), Functions can be selected from among 47)
Analog output (Frequency monitor)*6 1 point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current selectable)
Pulse output 1 point (MP terminal: 32 kHz max., 0 to 10 V)
RS-422 RJ45 connector (for Digital Operator)
RS-485 Control circuit terminal block, Modbus communication (Modbus-RTU)
USB USB1.1, mini-B connector
  Other functions AVR function, V/f characteristics switching, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S shape acceleration/deceleration, electronic thermal characteristics, level adjustment, restart function, torque boost function, fault monitor, soft lock function, frequency conversion display, USP function, motor 2 control function, UP/DWN, overcurrent control function, etc.
Ambient operating temperature *7 -10 to 50°C (However, derating is required).
Ambient storage temperature -20°C to 65°C
Ambient operating humidity 20% to 90% RH (with no condensation)
Vibration resistance 5.9 m/s2 (0.6G), 10 to 55 Hz
Application environment At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
EtherCAT Communication Unit 3G3AX-MX2-ECT
CompoNet Communication Unit 3G3AX-MX2-CRT-E
DeviceNet Communication Unit 3G3AX-MX2-DRT-E

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

Boost Your Business With Industrial Automation Products From United Automation

  • Best-in-class sourcing
  • MOQ starts from 1 piece
UP