Item | Specifications
Standard type High capacity type |
|||
Arrangement | 1 Form A | 1 Form C | 1 Form A | 1 Form C |
5 V DC | JQ1a-5V-F | JQ1-5V-F | JQ1aP-5V-F | JQ1P-5V-F |
6 V DC | JQ1a-6V-F | JQ1-6V-F | JQ1aP-6V-F | JQ1P-6V-F |
9 V DC | JQ1a-9V-F | JQ1-9V-F | JQ1aP-9V-F | JQ1P-9V-F |
12 V DC | JQ1a-12V-F | JQ1-12V-F | JQ1aP-12V-F | JQ1P-12V-F |
18 V DC | JQ1a-18V-F | JQ1-18V-F | JQ1aP-18V-F | JQ1P-18V-F |
24 V DC | JQ1a-24V-F | JQ1-24V-F | JQ1aP-24V-F | JQ1P-24V-F |
48 V DC | – | JQ1-48V-F | – | JQ1P-48V-F |
Contact resistance (Initial) | Max. 100 mΩ (By voltage drop 6 V DC 1 A) | |||
Contact material | AgSnO2 type | |||
Nominal switching capacity (resistive load) |
5 A 125 V AC, 2 A 250 V AC, 5 A 30 V DC |
N.O. side:
5 A 125 V AC, 2 A 250 V AC, 3 A 30 V AC N.C. side: 2 A 125 V AC, 1 A 250 V AC, 1 A 30 V DC |
10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC |
N.O. side: 10 A 125 V AC, 5 A 250 V AC,
5 A 30 V AC N.C. side: 3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC |
Max. switching power (resistive load) |
625 VA, 150 W |
N.O. side: 625 VA, 90 W
N.C. side: 250 VA, 30 W |
1,250 V AC, 150 W |
N.O. side: 1,250 VA, 150 W
N.C. side: 500 V AC, 30 W |
Max. switching voltage | 250 V AC, 110 V DC (0.3 A) | |||
Max. switching current | N.O.: 5 A, N.C.: 2 A | N.O.: 10 A, N.C.: 3 A | ||
Nominal operating power | 200 mW | 400 mW | 200 mW | 400 mW |
Min. switching capacity (reference value)*1 | 100 mA, 5 V DC | |||
Insulation resistance (Initial) | Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section. | |||
Between open contacts | 1,000 Vrms for 1 min. | 750 Vrms for 1 min. | 1,000 Vrms for 1 min. | 750 Vrms for 1 min. |
Between contact and coil | 4,000 Vrms for 1 min. (Detection current: 10 mA) | |||
Temperature rise (coil) |
Max. 45°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 5 A, at 70°C) |
Max. 45°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 10 A, at 70°C) |
||
Surge breakdown voltage*2 (Between contact and coil) (Initial) | 8,000 V | |||
Operate time (at nominal voltage) (at 20°C) (Initial) | Max. 20 ms (excluding contact bounce time.) | |||
Release time (at nominal voltage) (at 20°C) (Initial) | Max. 10 ms (excluding contact bounce time) (Without diode) | |||
Shock resistance Functional | 294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) | |||
Destructive | 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) | |||
Vibration resistance
Functional |
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10 µs.) | |||
Destructive | 10 to 55 Hz at double amplitude of 2.0 mm | |||
Mechanical (at 180 times / min.) | Min. 107 | |||
Conditions for operation, transport and storage*3 |
Ambient temperature: –40°C to +70°C (class E insulation),
–40°C to +85°C *4 (class B insulation) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) |
|||
Max. operating speed | 20 times / min. (at nominal switching capacity) | |||
Unit weight | Approx. 7 g |