Panasonic Power JQ Relays JQ1-5V-F/-6V-F/-9V-F/-12V-F JQ1-18V-F/-24V-F/-48V-F

Series#: Panasonic Power Relays

Product Details

Qty:

Specification

Item Specifications

Standard type High capacity type

Arrangement 1 Form A 1 Form C 1 Form A 1 Form C
5 V DC JQ1a-5V-F JQ1-5V-F JQ1aP-5V-F JQ1P-5V-F
6 V DC JQ1a-6V-F JQ1-6V-F JQ1aP-6V-F JQ1P-6V-F
9 V DC JQ1a-9V-F JQ1-9V-F JQ1aP-9V-F JQ1P-9V-F
12 V DC JQ1a-12V-F JQ1-12V-F JQ1aP-12V-F JQ1P-12V-F
18 V DC JQ1a-18V-F JQ1-18V-F JQ1aP-18V-F JQ1P-18V-F
24 V DC JQ1a-24V-F JQ1-24V-F JQ1aP-24V-F JQ1P-24V-F
48 V DC JQ1-48V-F JQ1P-48V-F
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1 A)
Contact material AgSnO2  type
 

 

 

Nominal switching capacity (resistive load)

 

 

5 A 125 V AC,

2 A 250 V AC,

5 A 30 V DC

N.O. side:

5 A 125 V AC,

2 A 250 V AC,

3 A 30 V AC

N.C. side:

2 A 125 V AC,

1 A 250 V AC,

1 A 30 V DC

 

 

10 A 125 V AC,

5 A 250 V AC,

5 A 30 V DC

N.O. side: 10 A 125 V AC, 5 A 250 V AC,

5 A 30 V AC

N.C. side:

3 A 125 V AC,

2 A 250 V AC,

1 A 30 V DC

 

Max. switching power (resistive load)

 

625 VA, 150 W

N.O. side: 625 VA, 90 W

N.C. side: 250 VA, 30 W

 

1,250 V AC, 150 W

N.O. side: 1,250 VA, 150 W

N.C. side: 500 V AC, 30 W

Max. switching voltage 250 V AC, 110 V DC (0.3 A)
Max. switching current N.O.: 5 A, N.C.: 2 A N.O.: 10 A, N.C.: 3 A
Nominal operating power 200 mW 400 mW 200 mW 400 mW
Min. switching capacity (reference value)*1 100 mA, 5 V DC
Insulation resistance (Initial) Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts 1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min.
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
 

Temperature rise (coil)

Max. 45°C

(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 5 A, at 70°C)

Max. 45°C

(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 10 A, at 70°C)

Surge breakdown voltage*2 (Between contact and coil) (Initial) 8,000 V
Operate time (at nominal voltage) (at 20°C) (Initial) Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C) (Initial) Max. 10 ms (excluding contact bounce time) (Without diode)
Shock resistance Functional 294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance

Functional

10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10 µs.)
Destructive 10 to 55 Hz at double amplitude of 2.0 mm
Mechanical (at 180 times / min.) Min. 107
 

Conditions for operation, transport and storage*3

Ambient temperature: –40°C to +70°C (class E insulation),

–40°C to +85°C *4 (class B insulation)

Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)

Max. operating speed 20 times / min. (at nominal switching capacity)
Unit weight Approx. 7 g