Panasonic Power LK-G Relays ALFG2PF09 ALFG2PF12 ALFG2PF18 ALFG2PF24

Series#: Panasonic Power Relays

Product Details

Qty:

Specification

Item Specifications
Type Standard type High capacity type
Contact Gap Contact Gap 1.5 mm .059 inch type Contact Gap 1.8 mm .071 inch type Contact Gap 1.5 mm .059 inch type Contact Gap 1.8 mm .071 inch type
Arrangement 1 Form A
Nominal coil voltage Standard type High capacity type Standard type High capacity type
9V DC ALFG1PF09 ALFG2PF09 ALFG1PF091 ALFG2PF091
12V DC ALFG1PF12 ALFG2PF12 ALFG1PF121 ALFG2PF121
18V DC ALFG1PF18 ALFG2PF18 ALFG1PF181 ALFG2PF181
24V DC ALFG1PF24 ALFG2PF24 ALFG1PF241 ALFG2PF241
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgSnO2 type
Nominal switching capacity 22A 250V AC 31A 250V AC 33A 250V AC
Max. switching power 5,500VA 7,750VA 8,250VA
Max. switching voltage 250V AC
Max. switching current 22A (AC) 31A (AC) 33A (AC)
Nominal operating power 1,400mW
Min. switching capacity (Reference value)*1 100mA 5V DC
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts 2,500 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*2 (Between contact and coil) (Initial) 6,000 V
 

Coil holding voltage*3

35 to 120%V (contact carrying current: 22A, at 20°C 68°F) 45 to 80%V (contact carrying current: 22A, at 85°C 185°F) 35 to 120%V (contact carrying current: 31A, at 20°C 68°F) 45 to 80%V (contact carrying current: 31A, at 85°C 185°F) 35 to 120%V (contact carrying current: 33A, at 20°C 68°F) 45 to 80%V (contact carrying current: 33A, at 85°C 185°F)
Operate time (at 20°C 68°F) (Initial) Max. 20 ms (at nominal coil voltage excluding contact bounce time.)
Release time (at 20°C 68°F) (Initial) Max. 10 ms (at nominal coil voltage excluding contact bounce time, without diode)
Shock resistance Functional Min. 100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Mechanical Contact Gap 1.5 mm .059 inch type: Min. 106 (at 180 times/min.)

Contact Gap 1.8 mm .071 inch type: Min. 5×105 (at 180 times/min.)

Electrical Resistive load 22A 250V AC, Min. 3×104

(at 20 times/min.)

 

 

Inductive load

Destructive: 22A 250V AC (cosφ = 0.8),

Min. 3×104 (on:off = 0.1s:10s) Over load: 35A 250V AC (cosφ = 0.8),

Min. 50 (on:off = 0.1s:10s)

Destructive: 31A 250V AC (cosφ = 0.8),

Min. 3×104 (on:off = 0.1s:10s) Over load: 47A 250V AC (cosφ = 0.8),

Min. 50 (on:off = 0.1s:10s)

Destructive: 33A 250V AC (cosφ = 0.8),

Min. 3×104 (on:off = 0.1s:10s) Over load: 50A 250V AC (cosφ = 0.8),

Min. 50 (on:off = 0.1s:10s)

 

Conditions for operation, transport and storage*4

Ambient temperature: –40°C to +60°C –40°F to +140°F (When nominal coil voltage applied)

–40°C to +85°C –40°F to +185°F (Coil holding voltage is when 45 to 80%V

of nominal coil voltage is applied.) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)

Air pressure: 86 to 106 kPa

Unit Weight Approx. 23 g .81 oz