Type | DC 2-wire type | ||||
Type | Front sensing | Top sensing | |||
Different frequency |
GL- 8FUx10 |
GL- 8FUBx10 |
GL- 8HUx10 |
GL- 8HUBx10 |
|
Different frequency | GL- 8FUIx10 |
GL- 8FUIBx10 |
GL- 8HUIx10 |
GL- 8HUIBx10 |
|
Max. operation distance (Note 2) | 2.5 mm 0.098 in ± 20 % | ||||
Stable sensing range (Note 2) | 0 to 1.8 mm 0 to 0.071 in | ||||
Standard sensing object | Iron sheet 15 x 15 x t 1 mm 0.591 x 0.591 x t 0.039 in |
||||
Hysteresis | 20 % or less of operation distance (with standard sensing object) |
||||
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | ||||
Current consumption | 0.8 mA or less (Note 3) | ||||
Output | Non-contact DC 2-wire type – Load current: 3 to 70 mA (Note 4) – Residual voltage: 3 V or less (Note 5) |
||||
Utilization category | DC-12 or DC-13 | ||||
Output operation | Normally open | Normally closed | Normally open | Normally closed | |
Short-circuit protection | Incorporated | ||||
Max. response frequency | 1kHz | ||||
Operation indicator | Orange LED (lights up when the output is ON) | ||||
Pollution degree | 3 (Industrial environment) | ||||
Protection | IP67 (IEC) | ||||
Ambient temperature | -25 to +70 ℃ -13 to +158 ℉, Storage: -30 to +80 ℃ -22 to +176 ℉ |
||||
Ambient humidity | 35 to 95 % RH, Storage: 35 to 95 % RH | ||||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
Insulation resistance | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | ||||
Material | Enclosure: Polyarylate | ||||
Cable | 0.15 mm2 2-core cabtyre cable, 1 m 3.281 ft long | ||||
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | ||||
Weight | Net weight : 12 g approx. |