Item | Specifications | ||
Contact arrangement | Nominal coil voltage | Single side stable | 2 coil latching |
2 Form C | 3 V DC | TX2SA-3V | TX2SA-LT-3V |
2 Form C | 4.5 V DC | TX2SA-4.5V | TX2SA-LT-4.5V |
2 Form C | 5 V DC | TX2SA-5V | TX2SA-LT-5V |
2 Form C | 6 V DC | TX2SA-6V | TX2SA-LT-6V |
2 Form C | 9 V DC | TX2SA-9V | TX2SA-LT-9V |
2 Form C | 12 V DC | TX2SA-12V | TX2SA-LT-12V |
2 Form C | 24 V DC | TX2SA-24V | TX2SA-LT-24V |
Arrangement | 2 Form C | ||
Initial contact resistance, max. | Max. 100 m▲ (By voltage drop 6 V DC 1A) | ||
Contact material | Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable) |
||
Nominal switching capacity | Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load) | ||
Max. switching power | Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load) | ||
Max. switching voltage | 220V DC | ||
Max. switching current | Standard contact: 2 A, AgPd contact: 1 A | ||
Min. switching capacity (Reference value)*1 | 10µA 10mV DC | ||
Single side stable | 140 mW (3 to 24 V DC) | ||
2 coil latching | 200 mW (3 to 24 V DC) | ||
Insulation resistance (Initial) | Min. 1,000M▲ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. | ||
Between open contacts | 1,000 Vrms for 1min. (Detection current: 10mA) | ||
Between contact and coil | 2,000 Vrms for 1min. (Detection current: 10mA) | ||
Between contact sets | 1,000 Vrms for 1min. (Detection current: 10mA) | ||
Temperature rise (at 20°C 68°F) | Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.) |
||
Operate time [Set time] (at 20°C 68°F) | Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) | ||
Release time [Reset time] (at 20°C 68°F) | Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) | ||
Shock resistance Functional | Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.) | ||
Destructive | Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) | ||
Vibration resistance Functional | 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.) | ||
Destructive | 10 to 55 Hz at double amplitude of 5 mm | ||
Mechanical | Min. 108 (at 180 cpm) | ||
Electrical (Standard contact) | Min. 105 (2 A 30 V DC resistive), 5×105 (1 A 30 V DC resistive) (at 20 cpm) | ||
Conditions for operation, transport and storage*2 |
Ambient temperature: –40°C to +85°C (up to 24 V coil) –40°F to +185°F (up to 24 V coil) [–40°C to +70°C (48 V coil) –40°F to +158°F (48 V coil)];
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) |
||
Max. operating speed (at rated load) | 20 cpm | ||
Weight | Approx. 2 g .071 oz |