Panasonic Signal TX Relays TX2SA-3V/-4.5V/-5V/-6V/-9V TX2SA-12V TX2SA-24V

Series#: Panasonic Signal Relays

Product Details

Qty:

Specification

Item Specifications
Contact arrangement Nominal coil voltage Single side stable 2 coil latching
2 Form C 3 V DC TX2SA-3V TX2SA-LT-3V
2 Form C 4.5 V DC TX2SA-4.5V TX2SA-LT-4.5V
2 Form C 5 V DC TX2SA-5V TX2SA-LT-5V
2 Form C 6 V DC TX2SA-6V TX2SA-LT-6V
2 Form C 9 V DC TX2SA-9V TX2SA-LT-9V
2 Form C 12 V DC TX2SA-12V TX2SA-LT-12V
2 Form C 24 V DC TX2SA-24V TX2SA-LT-24V
Arrangement 2 Form C
Initial contact resistance, max. Max. 100 m▲ (By voltage drop 6 V DC 1A)
Contact material Standard contact: Ag+Au clad,

AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)

Nominal switching capacity Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load)
Max. switching power Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load)
Max. switching voltage 220V DC
Max. switching current Standard contact: 2 A, AgPd contact: 1 A
Min. switching capacity (Reference value)*1 10µA 10mV DC
Single side stable 140 mW (3 to 24 V DC)
2 coil latching 200 mW (3 to 24 V DC)
Insulation resistance (Initial) Min. 1,000M▲ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Temperature rise (at 20°C 68°F) Max. 50°C

(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)

Operate time [Set time] (at 20°C 68°F) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Shock resistance Functional Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Mechanical Min. 108 (at 180 cpm)
Electrical (Standard contact) Min. 105 (2 A 30 V DC resistive), 5×105 (1 A 30 V DC resistive) (at 20 cpm)
 

Conditions for operation, transport and storage*2

Ambient temperature: –40°C to +85°C (up to 24 V coil) –40°F to +185°F (up to 24 V coil) [–40°C to +70°C (48 V coil) –40°F to +158°F (48 V coil)];

Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)

Max. operating speed (at rated load) 20 cpm
Weight Approx. 2 g .071 oz

 