Item | Schneider VFD Inverter Drive ATV630 0.75kW-75kW | |||
Mounting type | Cabinet integration | |||
Degree of protection | IP20 | |||
Power range for 50…60 Hz line supply | Three phase: 380…480 V (kW/HP) | 0.75…90/1…120 | ||
Three-phase: 400 V (kW) | – | |||
Three-phase: 440 V (kW) | – | |||
Three-phase: 480 V (HP) | – | |||
Three-phase: 500 (kW) | – | |||
Three-phase: 600 (HP) | – | |||
Three-phase: 690 (kW) | – | |||
Drive | Output frequency | 0.1… 500 Hz | ||
Control type | Asynchronous motor | Standard constant torque, variable standard torque, optimized torque mode | ||
Synchronous motor | PM (permanent magnet) motor, synchronous reluctance motor | |||
Functions | Advanced functions | Including all the advanced features of ATV600:b Accurate measurement for monitoring system energy consumption (deviation < 5%)
b Installation energy drift detection b Embedded Ethernet with direct access to system configuration and monitoring b Integration of actual pump curves to optimize the system operating point b Optimized pump monitoring based on actual operating point b Sensorless estimated flow rate b Measurements expressed in working units (e.g. m3/h, kWh/m3) b Limitation of overvoltage at the motor terminals b Contextual access to technical documentation through dynamic QR code b Continuous and historical real-time measurements with customizable dashboards b Predictive and preventive maintenance tracking functions (e.g. temperatures with PT100/1000 probe, fan monitoring) Easy setting of drive identification for Altivar Process Modular drives from 110 kW up to 800 kW (150…1100 HP) |
||
Integrated safety function | 1: STO (Safe Torque Off) SIL3 | |||
Number of preset speeds | 16 | |||
Number of integrated I/O | Analog inputs | 3: Configurable as voltage (0…10 V) or current (0-20 mA/4-20 mA), 2 of them including probes(PTC, PT100, PT1000, or KTY84) | ||
Digital inputs | 6: Voltage 24 V c (positive or negative logic) | |||
Digital output | – | |||
Analog outputs | 2: Configurable as voltage (0…10 V) or current (0-20 mA) | |||
Relay outputs | 3: 1 with NO/NC contacts and 2 with NO contacts | |||
Safety function inputs | 2: For safety function STO | |||
I/O expansion modules (optional) | Analog inputs | 2 differential analog inputs configurable via software as voltage (0…±10 V) orcurrent (0-20 mA/ 4-20 mA), or for PTC, PT100, or PT1000, 2- or 3-wire | ||
Digital inputs | 6: Voltage 24 V c (positive or negative logic) | |||
Digital outputs | 2: Assignable | |||
Relay output module (optional) | Relay outputs | 3: NO contacts | ||
Communication | Integrated | Modbus/TCP, Modbus serial link | ||
Option modules | Ethernet/IP, Modbus TCP and MD-Link dual port, CANopen Daisy chain, SUB-D and screwterminal block, PROFINET, PROFIBUS DP V1, DeviceNet, BACnet MS/TP, POWERLINK |