• 6ES7312 5BF04 0AB0 1 1
  • 6ES7312 5BF04 0AB0 2 1
  • 6ES7312 5BF04 0AB0 4 1
  • 6ES7312 5BF04 0AB0 6 1
  • 6ES7312 5BF04 0AB0 3 1
  • 6ES7312 5BF04 0AB0 5 1
  • 6ES7312 5BF04 0AB0 1 1
  • 6ES7312 5BF04 0AB0 2 1
  • 6ES7312 5BF04 0AB0 4 1
  • 6ES7312 5BF04 0AB0 6 1
  • 6ES7312 5BF04 0AB0 3 1
  • 6ES7312 5BF04 0AB0 5 1

Siemens PLCs SIMATIC S7-300 CPU 312C Compact CPU with MPI 6ES7312-5BF04-0AB0

Series#: Siemens PLC

Product Details

  • Siemens PLCs SIMATIC S7-300 CPU 312C Compact CPU with MPI 6ES7312-5BF04-0AB0
  • Siemens PLC Controller Module LOGO Series
  • We are First Class Siemens Supplier,siemens plc dealer and Siemens plc distributor in China.
  • We can Supply Siemens automation parts,such as Siemens PLC,Siemens Servo Motor,Siemens HMI,Siemens VFD and So on,
  • 100% Original and new,In stock by Siemens Automation
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Article number 6ES7312-5BF04-0AB0
CPU312C, 10DI/6DO, 64 KB
General information
HW functional status 01
Firmware version V3.3
Engineering with
 

● Programming package

 

STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
Supply voltage
Rated value (DC)
 

● 24 V DC

 

Yes
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
external protection for power supply lines (recommendation) Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A
Mains buffering
 

● Mains/voltage failure stored energy time

 

5 ms
 

● Repeat rate, min.

 

1 s
Digital outputs
 

— Rated value (DC)

 

24 V
 

— Reverse polarity protection

 

No
Input current
Current consumption (rated value) 570 mA
Current consumption (in no-load operation), typ. 90 mA
Inrush current, typ. 5 A
I²t 0.7 A²·s
Digital outputs
 

● from load voltage L+, max.

 

25 mA
Power loss
Power loss, typ. 8 W
Memory
Work memory
 

● integrated

 

64 kbyte
 

● expandable

 

No
 

● Size of retentive memory for retentive data blocks

 

64 kbyte
Load memory
 

● Plug-in (MMC)

 

Yes
 

● Plug-in (MMC), max.

 

8 Mbyte
 

● Data management on MMC (after last programming), min.

 

10 y
Backup
 

● present

 

Yes; Guaranteed by MMC (maintenance-free)
 

● without battery

 

Yes; Program and data
CPU processing times
for bit operations, typ. 0.1 µs
for word operations, typ. 0.24 µs
for fixed point arithmetic, typ. 0.32 µs
for floating point arithmetic, typ. 1.1 µs
CPU-blocks
Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
 

● Number, max.

 

1 024; Number range: 1 to 16000
 

● Size, max.

 

64 kbyte
FB
 

● Number, max.

 

1 024; Number range: 0 to 7999
 

● Size, max.

 

64 kbyte
FC
 

● Number, max.

 

1 024; Number range: 0 to 7999
 

● Size, max.

 

64 kbyte
OB
 

● Description

 

see instruction list
 

● Size, max.

 

64 kbyte
 

● Number of free cycle OBs

 

1; OB 1
 

● Number of time alarm OBs

 

1; OB 10
 

● Number of delay alarm OBs

 

2; OB 20, 21
 

● Number of cyclic interrupt OBs

 

4; OB 32, 33, 34, 35
 

● Number of process alarm OBs

 

1; OB 40
 

● Number of startup OBs

 

1; OB 100
 

● Number of asynchronous error OBs

 

4; OB 80, 82, 85, 87
 

● Number of synchronous error OBs

 

2; OB 121, 122
Nesting depth
 

● per priority class

 

16
 

● additional within an error OB

 

4
Counters, timers and their retentivity
S7 counter
 

● Number

 

256
Retentivity
 

— adjustable

 

Yes
 

— lower limit

 

0
 

— upper limit

 

255
 

— preset

 

Z 0 to Z 7
Counting range
 

— lower limit

 

0
 

— upper limit

 

999
IEC counter
 

● present

 

Yes
 

● Type

 

SFB
 

● Number

 

Unlimited (limited only by RAM capacity)
S7 times
 

● Number

 

256
Retentivity
 

— adjustable

 

Yes
 

— lower limit

 

0
 

— upper limit

 

255
 

— preset

 

No retentivity
Time range
 

— lower limit

 

10 ms
 

— upper limit

 

9 990 s
IEC timer
 

● present

 

Yes
 

● Type

 

SFB
 

● Number

 

Unlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in total all, max. 64 KB
Flag
 

● Number, max.

 

256 byte
 

● Retentivity available

 

Yes; MB 0 to MB 255
 

● Retentivity preset

 

MB 0 to MB 15
 

● Number of clock memories

 

8; 1 memory byte
Data blocks
 

● Retentivity adjustable

 

Yes; via non-retain property on DB
 

● Retentivity preset

 

Yes
Local data
 

● per priority class, max.

 

32 kbyte; Max. 2048 bytes per block

Unmatched Customer Service