• 6ES7326 2BF10 0AB0 2 1
  • 6ES7326 2BF10 0AB0 2 1
  • 6ES7326 2BF10 0AB0 2 1
  • 6ES7326 2BF10 0AB0 2 1

Siemens PLCs SIMATIC S7-300 digital output SM 326 Module 6ES7326-2BF10-0AB0

Series#: Siemens PLC

Product Details

  • Siemens PLCs SIMATIC S7-300 digital output SM 326 Module 6ES7326-2BF10-0AB0
  • Siemens PLC Controller Module LOGO Series
  • We are First Class Siemens Supplier,siemens plc dealer and Siemens plc distributor in China.
  • We can Supply Siemens automation parts,such as Siemens PLC,Siemens Servo Motor,Siemens HMI,Siemens VFD and So on,
  • 100% Original and new,In stock by Siemens Automation
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Article number 6ES7326-2BF10-0AB0 6ES7326-2BF41-0AB0
  SM326, F-DO10XDC24V/2A PP, failsafe SM 326, F-DO 8 X DC 24V/2A PM
Supply voltage    
Rated value (DC) 24 V; 1L+ 24 V; 1L+
Reverse polarity protection Yes Yes
Load voltage L+    
 

● Rated value (DC)

 

24 V; 2L+, 3L+ 24 V; 2L+, 3L+
 

● Reverse polarity protection

 

No No
Input current    
from supply voltage 1L+, max. 100 mA 75 mA
from load voltage 2L+ (without load), max. 100 mA 100 mA
from load voltage 3L+ (without load), max. 100 mA 100 mA
from backplane bus 5 V DC, max. 100 mA 100 mA
Power loss    
Power loss, typ. 6 W 12 W
Digital outputs    
Number of digital outputs 10 8
Short-circuit protection Yes Yes
Limitation of inductive shutdown voltage to   L+ (-33 V)
Switching capacity of the outputs    
 

● on lamp load, max.

 

5 W 5 W
Output voltage    
 

● for signal “1”, min.

 

L+ (-1.0 V) L+ (-1.0 V)
Output current    
 

● for signal “1” rated value

 

2 A 2 A
 

● for signal “1” permissible range for 0 to 40 °C, min.

 

7 mA 7 mA
 

● for signal “1” permissible range for 0 to 40 °C, max.

 

2.4 A 2 A; 2 A for horizontal installation, 1 A for vertical installation
 

● for signal “1” permissible range for 40 to 60 °C, min.

 

7 mA 7 mA
 

● for signal “1” permissible range for 40 to 60 °C, max.

 

2.4 A 1 A; for horizontal installation
 

● for signal “0” residual current, max.

 

0.5 mA 0.5 mA
Switching frequency    
 

● with resistive load, max.

 

25 Hz 30 Hz
 

● with inductive load, max.

 

25 Hz 2 Hz
 

● on lamp load, max.

 

10 Hz 10 Hz
Total current of the outputs (per group)    
horizontal installation    
 

— up to 40 °C, max.

 

10 A 7.5 A
 

— up to 60 °C, max.

 

6 A 5 A
vertical installation    
 

— up to 40 °C, max.

 

5 A 5 A
Cable length    
 

● shielded, max.

 

1 000 m 200 m; 200 m for SIL 3, AK 6, Cat 4
 

● unshielded, max.

 

600 m 200 m
Interrupts/diagnostics/status information    
Alarms    
 

● Diagnostic alarm

 

Yes Yes; Parameterizable
Diagnoses    
 

● Diagnostic information readable

 

Yes Yes
Diagnostics indication LED    
 

● Fail-safe operation

 

Yes Yes
 

● Group error SF (red)

 

Yes Yes
Potential separation    
Potential separation digital outputs    
 

● between the channels

 

Yes Yes
 

● between the channels, in groups of

 

5 4
 

● between the channels and backplane bus

 

Yes Yes
 

● between the channels and the power supply of the electronics

 

Yes Yes
Isolation    
Isolation tested with 370V for 1 min 500 V DC/350 V AC
Standards, approvals, certificates    
Highest safety class achievable in safety mode    
 

● acc. to DIN VDE 0801

 

AK 5 and 6  
 

● acc. to EN 954

 

Cat. 4 Cat. 4
 

● Performance level according to ISO 13849-1

 

e e
 

● SIL acc. to IEC 61508

 

SIL 3 SIL 3
Connection method    
required front connector 40-pin 40-pin
Dimensions    
Width 40 mm 80 mm
Height 125 mm 125 mm
Depth 120 mm 120 mm
Weights    
Weight, approx. 330 g 465 g

 

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

Boost Your Business With Industrial Automation Products From United Automation

  • Best-in-class sourcing
  • MOQ starts from 1 piece
UP