• 6ES7322 1HF10 0AA0 1
  • 6ES7322 1HF10 0AA0 1

Siemens PLCs SM 322 output modules 6ES7322-1HF10-0AA0 6ES7322-5HF00-0AB0

Series#: Siemens PLC

Product Details

  • Siemens PLCs SM 322 output modules 6ES7322-1HF10-0AA0 6ES7322-5HF00-0AB0
  • Digital outputs
  • For connecting solenoid valves, contactors, low-power motors, lamps and motor starters
  • 100% Original and new by Siemens company
  • 365 days warranty
  • Fast Shipping within 1 working day
Qty:

Specification

Article number

6ES7322-1FL00-0AA0

6ES7322-1HF01-0AA0

6ES7322-1HF10-0AA0

6ES7322-5HF00-0AB0

6ES7322-1HH01-0AA0

SM322, 32DO, 120/230V AC, 1A

SM322, 8DA, 24V DC/2A or 230V AC/2A

SM322, 8DA, 24V DC/5A OR 230V AC/5A

SM322, 8DO Relay, 24VDC, 120-230V AC, 5A

SM322, 16DO Relay

Load voltage L+

  • ● Rated value (DC)

24 V

120 V

24 V

120 V

  • ● permissible range, lower limit (DC)

24 V

  • ● permissible range, upper limit (DC)

120 V

Load voltage L1

  • ● Rated value (AC)

120 V; 120/230 V AC

230 V

230 V

230 V

  • ● permissible range, lower limit (AC)

79 V

  • ● permissible range, upper limit (AC)

264 V

  • ● permissible frequency range, lower limit

47 Hz

  • ● permissible frequency range, upper limit

63 Hz

Input current

from supply voltage L+, max.

160 mA

125 mA

160 mA

250 mA

from load voltage L1 (without load), max.

10 mA

from backplane bus 5 V DC, max.

190 mA

40 mA

40 mA

100 mA

100 mA

Power loss

Power loss, typ.

25 W

3.2 W

3.2 W

3.5 W

4.5 W

Digital outputs

Number of digital outputs

32

8; Relays

8; Relays

8; Relays

16; Relays

Short-circuit protection

No

No

No; to be provided externally

No; to be provided externally

No

Controlling a digital input

Yes

Yes

Yes

Yes

Yes

Size of motor starters according to NEMA, max.

Size 4 according to NEMA

Size 5 according to NEMA

Zero-crossing switch

Yes; Max. 60 V

Switching capacity of the outputs

  • ● on lamp load, max.

50 W

50 W

1 500 W; 230 V AC

1 500 W; 230 V AC

50 W; 230 V AC

  • ● Low energy/fluorescent lamps with electronic control gear

10x 58 W

10x 58 W

10x 58 W

  • ● Fluorescent tubes, conventionally compensated

1x 58 W

1x 58 W

1x 58 W

  • ● Fluorescent tubes, uncompensated

10x 58 W

10x 58 W

10x 58 W

Output voltage

  • ● for signal “1”, min.

L1 (-0.8 V)

Output current

  • ● for signal “1” rated value

1 A

2 A

5 A

5 A

2 A

  • ● for signal “1” permissible range for 0 to 40 °C, min.

10 mA

  • ● for signal “1” permissible range for 0 to 40 °C, max.

1 A

  • ● for signal “1” permissible range for 40 to 60 °C, min.

10 mA

  • ● for signal “1” permissible range for 40 to 60 °C, max.

1 A

  • ● for signal “1” minimum load current

10 mA

5 mA

5 mA

10 mA

10 mA

  • ● for signal “1” permissible surge current, max.

10 A; per group (for 2 AC cycles)

  • ● for signal “0” residual current, max.

2 mA

Output delay with resistive load

  • ● “0” to “1”, max.

1 AC cycle

  • ● “1” to “0”, max.

1 AC cycle

Parallel switching of two outputs

  • ● for uprating

No

No

No

No

No

  • ● for redundant control of a load

Yes; only outputs of the same group

Yes

Yes

Yes

Yes

Switching frequency

  • ● with resistive load, max.

10 Hz

2 Hz

2 Hz

2 Hz

1 Hz

  • ● with inductive load, max.

0.5 Hz

0.5 Hz

0.5 Hz

0.5 Hz

0.5 Hz

  • ● with inductive load (acc. to IEC 60947-5-1, AC15), max.

0.5 Hz

  • ● With inductive load (to IEC 60947-5-1, DC13/AC15), max.

0.5 Hz

0.5 Hz

0.5 Hz

0.5 Hz

  • ● on lamp load, max.

1 Hz

2 Hz

2 Hz

2 Hz

1 Hz

  • ● mechanical, max.

10 Hz

10 Hz

10 Hz

10 Hz

Total current of the outputs (per group)

horizontal installation

  • — up to 40 °C, max.

4 A

  • — up to 60 °C, max.

3 A

5 A

5 A

8 A

vertical installation

  • — up to 40 °C, max.

4 A

5 A

5 A

8 A

Relay outputs

  • ● Rated supply voltage of relay coil L+ (DC)

24 V; 110 mA

24 V

24 V

  • ● Contact connection (internal)

Yes; SIOV-CU4032 K275G

No

Yes; 330 Ohm, 0.1uF

No

  • ● Number of operating cycles, max.

300 000; 230 V AC: 100 000; 120 V AC: 200 000; 24 V DC: 300 000 (at 2 A)

300 000; 300 000 (24 V DC, at 2 A); 200 000 (120 V AC, at 3 A); 100 000 (230 V AC, at 3 A)

100 000; 100 000 (24 V DC, at 5 A), 100 000 (230 V AC, at 5 A)

100 000; 50 000 (24 V DC, at 2 A); 700 000 (120 V AC, at 2 A); 100 000 (230 V AC, at 2 A)

Switching capacity of contacts

  • — with inductive load, max.

2 A; 2 A (230 V AC), 2 A (24 V DC)

3 A; 3 A (230 V DC), 2 A (24 V AC)

5 A; 5 A (230 V DC), 5 A (24 V AC)

2 A; 2 A (230 V AC), 2 A (24 V DC)

  • — with resistive load, max.

2 A

8 A; 8 A (230 V DC), 5 A (24 V AC)

5 A; 5 A (230 V DC), 5 A (24 V AC)

2 A; 2 A (230 V AC), 2 A (24 V DC)

  • — Thermal continuous current, max.

3 A

8 A

5 A

2 A

Cable length

  • ● shielded, max.

1 000 m

1 000 m

1 000 m

1 000 m

1 000 m

  • ● unshielded, max.

600 m

600 m

600 m

600 m

600 m

Interrupts/diagnostics/status information

Alarms

No

No

No

Yes

No

Diagnostics function

Yes; Fuse blown or load voltage missing

No

No

Yes; Parameterizable

No

Alarms

  • ● Diagnostic alarm

No

No

No

Yes; Parameterizable

No

Diagnoses

  • ● Diagnostic information readable

Yes

  • ● Wire-break

No

No

No

  • ● Short-circuit

No

No

No

  • ● Fuse blown

No

No

No

  • ● missing load voltage

No

No

No

Diagnostics indication LED

  • ● Rated load voltage PWR (green)

No

No

No

  • ● Fuse OK FSG (green)

No

No

No

  • ● Group error SF (red)

Yes

Yes

  • ● Status indicator digital output (green)

Yes; per channel

Yes

Yes

Yes

Yes

Potential separation

Potential separation digital outputs

  • ● between the channels

Yes

Yes

Yes

Yes

Yes

  • ● between the channels, in groups of

8

2

1

1

8

  • ● between the channels and backplane bus

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

  • ● Between the channels and the power supply of the relays

Yes

Isolation

Isolation tested with

4 000 V DC

1 500 V AC

2 000 V AC

1 500 V AC

1 500 V AC

Connection method

required front connector

20-pin

20-pin

40-pin

40-pin

20-pin

Dimensions

Width

80 mm

40 mm

40 mm

40 mm

40 mm

Height

125 mm

125 mm

125 mm

125 mm

125 mm

Depth

117 mm

120 mm

120 mm

120 mm

120 mm

Weights

Weight, approx.

500 g

190 g

320 g

320 g

250 g

Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

Boost Your Business With Industrial Automation Products From United Automation

  • Best-in-class sourcing
  • MOQ starts from 1 piece
UP