Article number |
6ES7322-1FL00-0AA0 |
6ES7322-1HF01-0AA0 |
6ES7322-1HF10-0AA0 |
6ES7322-5HF00-0AB0 |
6ES7322-1HH01-0AA0 |
|
---|---|---|---|---|---|---|
SM322, 32DO, 120/230V AC, 1A |
SM322, 8DA, 24V DC/2A or 230V AC/2A |
SM322, 8DA, 24V DC/5A OR 230V AC/5A |
SM322, 8DO Relay, 24VDC, 120-230V AC, 5A |
SM322, 16DO Relay |
||
Load voltage L+ |
||||||
|
24 V |
120 V |
24 V |
120 V |
||
|
24 V |
|||||
|
120 V |
|||||
Load voltage L1 |
||||||
|
120 V; 120/230 V AC |
230 V |
230 V |
230 V |
||
|
79 V |
|||||
|
264 V |
|||||
|
47 Hz |
|||||
|
63 Hz |
|||||
Input current |
||||||
from supply voltage L+, max. |
160 mA |
125 mA |
160 mA |
250 mA |
||
from load voltage L1 (without load), max. |
10 mA |
|||||
from backplane bus 5 V DC, max. |
190 mA |
40 mA |
40 mA |
100 mA |
100 mA |
|
Power loss |
||||||
Power loss, typ. |
25 W |
3.2 W |
3.2 W |
3.5 W |
4.5 W |
|
Digital outputs |
||||||
Number of digital outputs |
32 |
8; Relays |
8; Relays |
8; Relays |
16; Relays |
|
Short-circuit protection |
No |
No |
No; to be provided externally |
No; to be provided externally |
No |
|
Controlling a digital input |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Size of motor starters according to NEMA, max. |
Size 4 according to NEMA |
Size 5 according to NEMA |
||||
Zero-crossing switch |
Yes; Max. 60 V |
|||||
Switching capacity of the outputs |
||||||
|
50 W |
50 W |
1 500 W; 230 V AC |
1 500 W; 230 V AC |
50 W; 230 V AC |
|
|
10x 58 W |
10x 58 W |
10x 58 W |
|||
|
1x 58 W |
1x 58 W |
1x 58 W |
|||
|
10x 58 W |
10x 58 W |
10x 58 W |
|||
Output voltage |
||||||
|
L1 (-0.8 V) |
|||||
Output current |
||||||
|
1 A |
2 A |
5 A |
5 A |
2 A |
|
|
10 mA |
|||||
|
1 A |
|||||
|
10 mA |
|||||
|
1 A |
|||||
|
10 mA |
5 mA |
5 mA |
10 mA |
10 mA |
|
|
10 A; per group (for 2 AC cycles) |
|||||
|
2 mA |
|||||
Output delay with resistive load |
||||||
|
1 AC cycle |
|||||
|
1 AC cycle |
|||||
Parallel switching of two outputs |
||||||
|
No |
No |
No |
No |
No |
|
|
Yes; only outputs of the same group |
Yes |
Yes |
Yes |
Yes |
|
Switching frequency |
||||||
|
10 Hz |
2 Hz |
2 Hz |
2 Hz |
1 Hz |
|
|
0.5 Hz |
0.5 Hz |
0.5 Hz |
0.5 Hz |
0.5 Hz |
|
|
0.5 Hz |
|||||
|
0.5 Hz |
0.5 Hz |
0.5 Hz |
0.5 Hz |
||
|
1 Hz |
2 Hz |
2 Hz |
2 Hz |
1 Hz |
|
|
10 Hz |
10 Hz |
10 Hz |
10 Hz |
||
Total current of the outputs (per group) |
||||||
horizontal installation |
||||||
|
4 A |
|||||
|
3 A |
5 A |
5 A |
8 A |
||
vertical installation |
||||||
|
4 A |
5 A |
5 A |
8 A |
||
Relay outputs |
||||||
|
24 V; 110 mA |
24 V |
24 V |
|||
|
Yes; SIOV-CU4032 K275G |
No |
Yes; 330 Ohm, 0.1uF |
No |
||
|
300 000; 230 V AC: 100 000; 120 V AC: 200 000; 24 V DC: 300 000 (at 2 A) |
300 000; 300 000 (24 V DC, at 2 A); 200 000 (120 V AC, at 3 A); 100 000 (230 V AC, at 3 A) |
100 000; 100 000 (24 V DC, at 5 A), 100 000 (230 V AC, at 5 A) |
100 000; 50 000 (24 V DC, at 2 A); 700 000 (120 V AC, at 2 A); 100 000 (230 V AC, at 2 A) |
||
Switching capacity of contacts |
||||||
|
2 A; 2 A (230 V AC), 2 A (24 V DC) |
3 A; 3 A (230 V DC), 2 A (24 V AC) |
5 A; 5 A (230 V DC), 5 A (24 V AC) |
2 A; 2 A (230 V AC), 2 A (24 V DC) |
||
|
2 A |
8 A; 8 A (230 V DC), 5 A (24 V AC) |
5 A; 5 A (230 V DC), 5 A (24 V AC) |
2 A; 2 A (230 V AC), 2 A (24 V DC) |
||
|
3 A |
8 A |
5 A |
2 A |
||
Cable length |
||||||
|
1 000 m |
1 000 m |
1 000 m |
1 000 m |
1 000 m |
|
|
600 m |
600 m |
600 m |
600 m |
600 m |
|
Interrupts/diagnostics/status information |
||||||
Alarms |
No |
No |
No |
Yes |
No |
|
Diagnostics function |
Yes; Fuse blown or load voltage missing |
No |
No |
Yes; Parameterizable |
No |
|
Alarms |
||||||
|
No |
No |
No |
Yes; Parameterizable |
No |
|
Diagnoses |
||||||
|
Yes |
|||||
|
No |
No |
No |
|||
|
No |
No |
No |
|||
|
No |
No |
No |
|||
|
No |
No |
No |
|||
Diagnostics indication LED |
||||||
|
No |
No |
No |
|||
|
No |
No |
No |
|||
|
Yes |
Yes |
||||
|
Yes; per channel |
Yes |
Yes |
Yes |
Yes |
|
Potential separation |
||||||
Potential separation digital outputs |
||||||
|
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
8 |
2 |
1 |
1 |
8 |
|
|
Yes; Optocoupler |
Yes; Optocoupler |
Yes; Optocoupler |
Yes; Optocoupler |
Yes; Optocoupler |
|
|
Yes |
|||||
Isolation |
||||||
Isolation tested with |
4 000 V DC |
1 500 V AC |
2 000 V AC |
1 500 V AC |
1 500 V AC |
|
Connection method |
||||||
required front connector |
20-pin |
20-pin |
40-pin |
40-pin |
20-pin |
|
Dimensions |
||||||
Width |
80 mm |
40 mm |
40 mm |
40 mm |
40 mm |
|
Height |
125 mm |
125 mm |
125 mm |
125 mm |
125 mm |
|
Depth |
117 mm |
120 mm |
120 mm |
120 mm |
120 mm |
|
Weights |
||||||
Weight, approx. |
500 g |
190 g |
320 g |
320 g |
250 g |